UP
DOWN
A
t Q1
B
X4_CLK
(see note)
X2_CLK
(see note)
t Q2
X1_CLK
(see note)
NOTE. x1, x2 and x4 CLKs are internal Up/Down clocks derived from filtered and decoded quadrature clocks.
FIGURE 5. A/B QUADRATURE CLOCKS vs INTERNAL COUNT CLOCKS
UP
A
B
X4_CLK
DOWN
CNTR FFFFFC FFFFFD
FLGa
FLGb
(up/dn)
FFFFFE
FFFFFF 000000 000001 000002
t fda
CY
(SHOWN WITH PR=000OO1)
CMP
t fw
FLGb
positive
(sign)
t nt
INT/
000001 000000 FFFFFF FFFFFE FFFFFD
BW
t fdb
negative
NOTE. FLGa is in non-latched mode.
FIGURE 6. QUADRATURE CLOCKS vs FLGa, FLGb and INT/ OUTPUTS
7566R-121605-10