DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAPD-009918-C209C0 데이터 시트보기 (PDF) - M/A-COM Technology Solutions, Inc.

부품명
상세내역
제조사
MAPD-009918-C209C0
MA-COM
M/A-COM Technology Solutions, Inc. MA-COM
MAPD-009918-C209C0 Datasheet PDF : 4 Pages
1 2 3 4
MAPD-009918-C209C0
2 Way 0º Power Divider
5 to 1000 MHz
Electrical Specifications: TA = 25°C, 0dBm, Z0 = 75, Pin = 0dBm
Parameter
Test Conditions
Units
Min
Typ
Insertion Loss (Above 3dB)
5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
-
0.53
dB
-
0.57
dB
-
0.72
Amplitude Balance
5 - 1000 MHz
-
dB
0.3
Phase Balance
Input Return Loss
5 - 1000 MHz
5 - 1000 MHz
º
-
0.9
dB
20
29
Output Return Loss
5 - 50 MHz
50 - 1000 MHz
Isolation (between outputs)
5 - 50 MHz
50 - 1000MHz
Recommended Maximum Ratings
Parameter
Value
Input power
Internal Load Dissipation
Operating Temperature
Storage Temperature
1W
0.125W
-40°C to +85°C
-40°C to +85°C
Recommended PCB Configuration
dB
18
23
dB
20
29
dB
26
40
dB
30
38
Application Circuit
Rev. V1
Max
0.7
0.8
1.0
± 0.6
± 4.0
-
-
-
-
-
-
-
-
REF DESCRIPTION P/N VENDOR
R1 RES,0402
240ROHM
L1 IND,0402
L2 IND,0402
8.2nH COILCRAFT
8.2nH COILCRAFT
C1 CAP,0402
0.5pF MURATA
C2 CAP,0402
0.5pF MURATA
2
ADVANCED: Data Sheets contain information regarding a product MA-COM Technical Solutions is North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
considering for development. Performance is based on target specifications, simulated results, and/
or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product MA-COM Technical Solutions
India Tel: +91.80.43537383
China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
has under development. Performance is based on engineering tests. Specifications are typical.
Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commit- M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
ment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.

Share Link: 