Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
Table 5. Command-Byte Bit Assignments
REGISTER
RLTS
RRTE
RSL
RCL
RCRA
RLHN
RLLI
RRHI
RRLS
WCA
WCRW
WLHO
WLLM
WRHA
WRLN
OSHT
REET
RIET
RWOE
RWOI
HYS
QUEUE
ADDRESS
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
19h
20h
21h
22h
FEh
FFh
POR STATE
0000 0000
0°C
0000 0000
0°C
N/A
0000 0000
0000 0111
0101 0101
+85°C
0000 0000
0°C
0101 0101
+85°C
0000 0000
0°C
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0000 0000
0°C
0000 0000
0°C
0110 1110
+110°C
0101 0101
+85°C
0101 0101
+85°C
0000 1010
10°C
1000 0000
0100 1101
0101 1001
FUNCTION
Read local (internal) temperature
Read remote (external) temperature
Read status byte
Read configuration byte
Read conversion rate byte
Read local (internal) ALERT high limit
Read local (internal) ALERT low limit
Read remote (external) ALERT high limit
Read remote (external) ALERT low limit
Write configuration byte
Write conversion rate byte
Write local (internal) ALERT high limit
Write local (internal) ALERT low limit
Write remote (external) ALERT high limit
Write remote (external) ALERT low limit
One-shot
Read remote (external) extended temperature
Read local (internal) extended temperature
Read/write remote (external) OVERT limit (MAX6648)
Read/write remote (external) OVERT limit (MAX6692)
Read/write local (internal) OVERT limit
Overtemperature hysteresis
Fault queue
Read manufacture ID
Read revision ID
Table 6. Configuration-Byte Bit Assignments (03h)
BIT
7 (MSB)
6
5 to 0
NAME
MASK
RUN
RFU
POR STATE
0
0
0
FUNCTION
Masks ALERT interrupts when set to 1.
Standby mode control bit; if set to 1, standby mode is initiated.
Reserved.
only at the 3 LSBs of this register, so the upper 5 bits
are don’t care bits, which should be set to zero. The
conversion rate tolerance is ±25% at any rate setting.
Valid A/D conversion results for both channels are avail-
able one total conversion time (125ms nominal, 156ms
maximum) after initiating a conversion, whether conver-
sion is initiated through the RUN bit, one-shot com-
mand, or initial power-up. Changing the conversion rate
can also affect the delay until new results are available.
Slave Addresses
The MAX6648/MAX6692 have a fixed address of 1001
100. The MAX6648/MAX6692 also respond to the
SMBus alert response slave address (see the Alert
Response Address section).
POR and UVLO
To prevent ambiguous power-supply conditions from
corrupting the data in memory and causing erratic
behavior, a POR voltage detector monitors VCC and
10 ______________________________________________________________________________________