DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6956AAX 데이터 시트보기 (PDF) - Maxim Integrated

부품명
상세내역
제조사
MAX6956AAX Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
2-Wire-Interfaced, 2.5V to 5.5V, 20-Port or
28-Port LED Display Driver and I/O Expander
HOW COMMAND BYTE AND DATA BYTE MAP INTO MAX6956's REGISTER
ACKNOWLEDGE FROM MAX6956
ACKNOWLEDGE FROM MAX6956
D15 D14 D13 D12 D11 D10 D9 D8
ACKNOWLEDGE FROM MAX6956
D7 D6 D5 D4 D3 D2 D1 D0
S
SLAVE ADDRESS
0A
COMMAND BYTE
A
DATA BYTE
AP
R/W
Figure 10. n Data Bytes Received
n BYTES
AUTOINCREMENT MEMORY WORD ADDRESS
Table 3. MAX6956 Address Map
PIN
CONNECTION
AD1
GND
AD0
GND
GND
GND
V+
SDA
GND
V+
V+
V+
V+
SDA
SDA
SDA
SDA
SCL
SCL
SCL
SCL
SCL
GND
V+
SDA
SCL
GND
V+
SDA
SCL
GND
V+
SDA
SCL
DEVICE ADDRESS
A6
A5
A4
A3
A2
A1
A0
1
0
0
0
0
0
0
1
0
0
0
0
0
1
1
0
0
0
0
1
0
1
0
0
0
0
1
1
1
0
0
0
1
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
0
0
1
1
1
1
0
0
1
0
0
0
1
0
0
1
0
0
1
1
0
0
1
0
1
0
1
0
0
1
0
1
1
1
0
0
1
1
0
0
1
0
0
1
1
0
1
1
0
0
1
1
1
0
1
0
0
1
1
1
1
Table 4. Autoincrement Rules
COMMAND BYTE ADDRESS RANGE
x0000000 to x1111110
x1111111
AUTOINCREMENT BEHAVIOR
Command address autoincrements after byte read or written
Command address remains at x1111111 after byte written or read
ing a write (Figure 8). The master can now read n con-
secutive bytes from the MAX6956, with the first data
byte being read from the register addressed by the ini-
tialized command byte. When performing read-after-
write verification, remember to reset the command
byte’s address because the stored control byte
address generally has been autoincremented after the
write (Table 4). Table 5 is the register address map.
Operation with Multiple Masters
If the MAX6956 is operated on a 2-wire interface with
multiple masters, a master reading the MAX6956
should use a repeated start between the write, which
sets the MAX6956’s address pointer, and the read(s)
that takes the data from the location(s). This is because
it is possible for master 2 to take over the bus after
master 1 has set up the MAX6956’s address pointer but
before master 1 has read the data. If master 2 subse-
______________________________________________________________________________________ 11