Serially Interfaced, 8-Digit LED Display Drivers
Table 2. Register Address Map
REGISTER
No-Op
Digit 0
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
Digit 6
Digit 7
Decode
Mode
Intensity
Scan Limit
Shutdown
Display
Test
ADDRESS
HEX
D15–
D12
D11 D10
D9
D8
CODE
X
0000
X0
X
0001
X1
X
0010
X2
X
0011
X3
X
0100
X4
X
0101
X5
X
0110
X6
X
0111
X7
X
1000
X8
X
1001
X9
X
1010
XA
X
1011
XB
X
1100
XC
X
1111
XF
Initial Power-Up
On initial power-up, all control registers are reset, the
display is blanked, and the MAX7219/MAX7221 enter
shutdown mode. Program the display driver prior to
display use. Otherwise, it will initially be set to scan one
digit, it will not decode data in the data registers, and
the intensity register will be set to its minimum value.
Decode-Mode Register
The decode-mode register sets BCD code B (0-9, E, H,
L, P, and -) or no-decode operation for each digit. Each
bit in the register corresponds to one digit. A logic high
selects code B decoding while logic low bypasses the
decoder. Examples of the decode mode control-regis-
ter format are shown in Table 4.
When the code B decode mode is used, the decoder
looks only at the lower nibble of the data in the digit
registers (D3–D0), disregarding bits D4–D6. D7, which
sets the decimal point (SEG DP), is independent of the
decoder and is positive logic (D7 = 1 turns the decimal
point on). Table 5 lists the code B font.
When no-decode is selected, data bits D7–D0 corre-
spond to the segment lines of the MAX7219/MAX7221.
Table 6 shows the one-to-one pairing of each data bit
to the appropriate segment line.
Table 3. Shutdown Register Format (Address (Hex) = XC)
REGISTER DATA
MODE
ADDRESS CODE
(HEX)
D7
D6
D5
D4
D3
D2
D1
D0
Shutdown
Mode
Normal
Operation
XC
X
X
X
X
X
X
X
0
XC
X
X
X
X
X
X
X
1
Table 4. Decode-Mode Register Examples (Address (Hex) = X9)
DECODE MODE
No decode for digits 7–0
Code B decode for digit 0
No decode for digits 7–1
Code B decode for digits 3–0
No decode for digits 7–4
Code B decode for digits 7–0
REGISTER DATA
HEX
D7
D6
D5
D4
D3
D2
D1
D0
CODE
0
0
0
0
0
0
0
0
00
0
0
0
0
0
0
0
1
01
0
0
0
0
1
1
1
1
0F
1
1
1
1
1
1
1
1
FF
_______________________________________________________________________________________ 7