MB90570A/570C Series
The series without built-in step-down circuit have no oscillation setting time of step-down circuit, so outputs
should not become indeterminate. (MB90F574A,MB90574C)
Timing chart of indeterminate outputs from ports 0 and 1
Oscillation setting time *2
VCC (power-supply pin)
PONR (power-on reset) signal
RST (external asynchronous reset) signal
RST (internal reset) signal
Oscillation clock signal
KA (internal operating clock A) signal
KB (internal operating clock B) signal
PORT (port output) signal
Step-down circuit setting time *1
Period of indeterminate
*1: Step-down circuit setting time 217/oscillation clock frequency (oscillation clock frequency of 16 MHz: 8.19 ms)
*2: Oscillation setting time
218/oscillation clock frequency (oscillation clock frequency of 16 MHz: 16.38 ms)
12. Initialization
In the device, there are internal registers which are initialized only by a power-on reset. Turn on the power again
to initialize these registers.
13. Return from standby state
If the power-supply voltage goes below the standby RAM holding voltage in the standby state, the device may
fail to return from the standby state. In this case, reset the device via the external reset pin to return to the normal
state.
14. Precautions for Use of ’DIV A, Ri,’ and ’DIVW A, Ri’ Instructions
The signed multiplication-division instructions ’DIV A, Ri,’ and ’DIVW A, RWi’ should be used when the corre-
sponding bank registers (DTB, ADB, USB, SSB) are set to value ’00h.’ If the corresponding bank registers (DTB,
ADB, USB, SSB) are set to a value other than ’00h,’ then the remainder obtained after the execution of the
instruction will not be placed in the instruction operand register.
15. Precautions for Use of REALOS
Extended intelligent I/O service (EI2OS) cannot be used, when REALOS is used.
16. Caution on PLL Clock Mode
If the PLL clock mode is selected, the microcontroller attempt to be working with the self-oscillating circuit even
when there is no external oscillator or external clock input is stopped. Performance of this operation, however,
cannot be guaranteed.