MC10SX1130
10 W
10 W
+5.0 V
SUPPLY
DECOUPLING
CAPACITORS
16
15
14
13
12
11
10
9
VEE
Stretch
VEE
IOUT
RSET
IOUT
VCC
VEE
VEE
VCC
VBB
DIN
DIN
RTCO1
RTCO2
VEE
1
2
3
4
5
6
7
8
PECL
BIAS
50 W
IN
50 W
IN
1 kW
PECL
BIAS
Figure 3. Typical +5 V Applications Circuit
Table 2. ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
VEE
Power Supply (VCC = 0 V)
VI
Input Voltage (VCC = 0 V)
Iout
Output Current Continuous
Surge
−7.0 to 0
0 to −6.0
100
110
VDC
VDC
mA
TA
Operating Temperature Range
−40 to +85
°C
VEE
Operating Range (VCC = 0)
−5.5 to −4.5
VDC
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
http://onsemi.com
3