Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM100RSD060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
100 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Control Sector
Over Current Trip Level Inverter Part
OC
(VD = 15V)
Over Current Trip Level Brake Part
OC
Short Circuit Trip Level Inverter Part
SC
Short Circuit Trip Level Brake Part
Tj = -20°C
—
Tj = 25°C
264
Tj = 125°C
158
-20°C ≤ Tj ≤ 125°C, VD = 15V
39
-20°C ≤ Tj ≤ 125°C, VD = 15V
—
—
Over Current Delay Time
Over Temperature Protection (VD = 15V)
(Lower Arm)
Supply Circuit Under Voltage Protection
toff(OC)
OT
OTR
UV
VD = 15V
—
Trip Level
111
Reset Level
—
Trip Level
11.5
(-20 ≤ Tj ≤ 125°C)
UVR
Reset Level
—
Circuit Current
ID
VD = 15V, VCIN = 15V, VN1-VNC
—
VD = 15V, VCIN = 15V, VXP1-VXPC
—
Input ON Threshold Voltage
VCIN(on)
Applied between
1.2
Input OFF Threshold Voltage
VCIN(off)
UP, VP, WP, UN, VN, WN, Br-VNC
1.7
Fault Output Current*
IFO(H)
VD = 15V, VCIN = 15V
—
IFO(L)
VD = 15V, VCIN = 15V
—
Minimum Fault Output Pulse Width*
tFO
VD = 15V
1.0
*Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower devide operate to protect it.
Typ.
—
311
—
53
360
79
10
118
100
12.0
12.5
44
13
1.5
2.0
—
10
1.8
Max. Units
520 Amperes
430 Amperes
— Amperes
— Amperes
— Amperes
— Amperes
—
µS
125
°C
—
°C
12.5 Volts
—
Volts
60
mA
18
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
—
mS
4