NJU6680
127 128 1 2 3 4 5 6 7 8 9 10 11 12 13
CL
FR
127 128 1 2 3 4 5 6 7 8 9 10 11 12 13
COM0
COM1
SEGn
n=5, Duty cycle ratio=1/128
Fig. 2-2. LCD diving waveforms in the n-line inversion mode
(d) Oscillator
The internal oscillator is used to create internal clocks for the display timing signals (CL, FR) and the
voltage converter.
- 14 -
14
Ver.2003-04-08