NJU9214
(2-2-2) Range setting ( Push type switch : KMS = " L ", RMS = " X " )
The range setting shown in below table is available with the " RANGE " switch.
When the switch is pressed once, the range is changed from auto to manual, and it’s range is held.
Then, the range is changed in every time by the switch operation. When the switch is pressed over
than 1 second, the range always returns to Auto-range is possible from any range statuses.
1push(>1sec)
Measurement Mode
Auto
Manual
Range up
Range Control
1push(<1sec) 1push(<1sec)
DCV
ACV
D C mA
A C mA
Resistance ( )
Continuity ( )
R1 to R5
R1 to R5
R2 to R3
R2 to R3
R1 to R6
HOLD
RiRi+1
(R5R1)
(R5R1)
(R3R2)
(R3R2)
(R6R1)
400mV to 4000V
400mV to 4000V
40mA to 400mA
40mA to 400mA
400Ω to 40MΩ
Diode ( )
ADP
FIXED
DCA
ACA
Frequency ( f )
Tacho ( rpm )
Capacitance ( C )
R1 to R5
R1 to R3
R1 to R6
HOLD
Auto – range
RiRi+1 (R6R1)
100Hz to 999.9kHz
6000rpm to 600krpm
4nF to 400uF
( NOTE ) Frequency measurement and Tacho are always set to the auto-range.
Default
Range
4V
4V
40mA
40mA
400
400
4V
400mV
40A
40A
100Hz
6000rpm
4nF
Ranges of continuity test (
), diode check (
), ADP, DCA and ACA measurements are
always fixed to their default ranges.
Just after power-on operation or changing mode, their ranges are set to the default range.
In the ADP measurement, 3 units are displayed by setting of RC1 to RC3 terminals.
The R1 to R6 of above range control table are set a range corresponding to below table.
RANGE DCV
ACV
DCmA
ACmA
f
R1
400mV 400mA
400
100Hz
R2
4V
4V
40mA
40mA
4k
1000Hz
R3
40V
40V
400mA
400mA
40k
10kHz
R4
400V
400V
400k
100kHz
R5
4000V
4000V
4000k1000kHz
R6
40M
( NOTE ) The " " mark means the default range.
rpm
6000
60000
600k
C
4nF
40nF
400nF
4uF
40uF
400uF
Changing to DC400mV range or AC400mV range is available by only manual operation. Auto-range operation
cannot change to these ranges.
When the auto-range is switched in DC400mV or AC400mV range, measurement is continued in the 400mV
range. When overflow occurs in 400mV of the auto-range, its range changes to 4V range automatically.