Philips Semiconductors
FLEXroaming decoder II
Product specification
PCD5013
8.5.5.3 Receiver warm-up setting packets
(ID = 11H to 15H)
CLS: control line setting (Table 22). This is the value to be
output on the receiver control lines (S0 to S7) for this
receiver warm-up state. Value after reset = 0.
SE: step enable (Table 22). The receiver setting is
enabled when the bit is set. If the bit is cleared then that
step in the receiver warm-up sequence is disabled and all
following steps are ignored. Value after reset = 0.
LBC: low battery check (Table 22). If this bit is set, the
PCD5013 checks the status of the LOBAT port just before
leaving this receiver warm-up state. Value after reset = 0.
ST: step time (Table 22). This sets the duration time for
receiver warm-up until the next receiver state. The setting
is in 625 µs steps and valid values are:
625 µs (ST = 01H) to 79.375 ms (ST = 7FH).
Value after reset = 01H.
s: setting number, see Tables 21 and 22 for the s names
and values and location in the receiver warm-up packet.
Table 21 Receiver warm-up setting numbers
s3
s2
s1
s0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
Table 22 Receiver warm-up setting packet bit assignments
BYTE
3
2
1
0
BIT 7
0
SE
CLS7
0
BIT 6
0
0
CLS6
ST6
BIT 5
0
0
CLS5
ST5
BIT 4
1
0
CLS4
ST4
SETTING NAME
warm-up 1
warm-up 2
warm-up 3
warm-up 4
warm-up 5
BIT 3
s3
LBC
CLS3
ST3
BIT 2
s2
0
CLS2
ST2
BIT 1
s1
0
CLS1
ST1
BIT 0
s0
0
CLS0
ST0