DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PCF2129T 데이터 시트보기 (PDF) - NXP Semiconductors.

부품명
상세내역
제조사
PCF2129T Datasheet PDF : 73 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NXP Semiconductors
PCF2129T
Accurate RTC with integrated quartz crystal for industrial
8. Functional description
The PCF2129T is a Real Time Clock (RTC) and calendar with an on-chip Temperature
Compensated Crystal (Xtal) Oscillator (TCXO) and a 32.768 kHz quartz crystal integrated
into the same package (see Section 8.3.2).
Address and data are transferred by a selectable 400 kHz Fast-mode I2C-bus or a 3 line
SPI-bus with separate data input and output (see Section 9). The maximum speed of the
SPI-bus is 6.5 Mbit/s.
The PCF2129T has a backup battery input pin and backup battery switch-over circuit
which monitors the main power supply. The backup battery switch-over circuit
automatically switches to the backup battery when a power failure condition is detected
(see Section 8.5.1). Accurate timekeeping is maintained even when the main power
supply is interrupted.
A battery low detection circuit monitors the status of the battery (see Section 8.5.3). When
the battery voltage drops below a certain threshold value, a flag is set to indicate that the
battery must be replaced soon. This ensures the integrity of the data during periods of
battery backup.
8.1 Register overview
The PCF2129T contains an auto-incrementing address register: the built-in address
register will increment automatically after each read or write of a data byte up to the
register 1Bh. After register 1Bh, the auto-incrementing will wrap around to address 00h
(see Figure 3).
address register
00h
01h
02h
03h
...
19h
1Ah
1Bh
auto-increment
wrap around
001aaj398
Fig 3. Handling address registers
The first three registers (memory address 00h, 01h, and 02h) are used as control
registers (see Section 8.2).
The memory addresses 03h through to 09h are used as counters for the clock
function (seconds up to years). The date is automatically adjusted for months with
fewer than 31 days, including corrections for leap years. The clock can operate in
12-hour mode with an AM/PM indication or in 24-hour mode (see Section 8.8).
The registers at addresses 0Ah through 0Eh define the alarm function. It can be
selected that an interrupt is generated when an alarm event occurs (see Section 8.9).
PCF2129T
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 12 February 2013
© NXP B.V. 2013. All rights reserved.
5 of 73

Share Link: 