PM6600
Electrical characteristics
Table 6. Electrical characteristics (continued)
Symbol
Parameter
Test condition
Values
Unit
Min Typ Max
Soft start and power management
EN, Turn-On level threshold
EN, Turn-Off level threshold
DIM, high level threshold
DIM, low level threshold
EN, Pull-up current
SS, charge current
SS, End-Of-Startup threshold
SS, Reduced switching frequency
Release threshold
Current generators section
TDIM-ON,min
KR
∆IROWx
VIFB
VTH,FAULT
Minimum dimming On-Time
ROWs current coefficient
accuracy
ROWs current mismatch(1)
Feedback regulation voltage
Shorted LED fault detection
threshold
VFAULT,LOW FAULT pin low-level voltage
Thermal shutdown
RRILIM = 51 kΩ
RRILIM = 51 kΩ
RRILIM = 51 kΩ
No LEDs mismatch
IFAULT,SINK = 4 mA
TSHDN
Thermal shutdown
Turn-off temperature
1.6
V
0.8
1.3
0.8
2.5
µA
4
5
6
2
2.4
2.8
V
0.8
500
ns
998 ±21 V
±2
%
400
mV
8.2
V
350 mV
150
°C
Note:
The Current Mismatch is the maximum current difference among the ROWs of one device.