ECONOLINE
DC/DC-Converter
RS-S_D(Z)
Series
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
Input Voltage Range
2:1 and 4:1
Output Accuracy
±2% typ.
Line Voltage Regulation
±0.5% max.
Load Voltage Regulation
20%-100% Load
±0.5% max.
Minimum Load
10% (2)
Output Ripple and Noise (20MHz limited)
50mVp-p max.
Switching Frequency
Full Load
100kHz min. / 300kHz max.
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
Isolation Voltage
Isolation Capacitance
Standard
/H2 Version
/H3 Version
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
RS-05xxS_D
RS-12xxS_D
RS-24xxS_D, SZ_DZ
RS-48xxS_D, SZ_DZ
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max
Isolation Resistance
1GΩ min.
Short Circuit Protection
Operating Temperature Range
2:1
(No Derating)
4:1
Continuous
–40°C to +85°C
–40°C to +75°C
Storage Temperature Range
–55°C to +125°C
Relative Humidity
95% RH
Package Weight
4.7g
Packing Quantity
22 pcs per Tube
} MTBF (+25°C)
(+85°C)
Detailed Information see
Application Notes chapter "MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
1398 x 103 hours
210 x 103 hours
Certifications
EN General Safety
Report: SPCLVD1605077-10
EN60950-1, AM2:2013
EN Medical Safety
Report: MDD1205098-3 + RM1205098-3
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL General Safety
Report: E224736-A35
UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1:
Note 2:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-power.com