ELECTRICAL DATA
S3C72H8/P72H8
Table 16-2. D.C. Electrical Characteristics (Continued)
(TA = – 40 °C to + 85 °C, VDD = 1.8 V to 5.5 V)
Parameter Symbol
Conditions
Min
Typ
Max
Units
Supply
Current (note)
IDD1 Main operation mode:
VDD = 5 V ± 10%, 6-MHz crystal
VDD = 5 V ± 10%, 4.19 MHz
VDD = 3 V ± 10%, 6-MHz crystal
VDD = 3 V ± 10%, 4.19 MHz
IDD2 Main Idle mode:
VDD = 5 V ± 10%, 6-MHz crystal
VDD = 5 V ± 10%, 4.19 MHz
VDD = 3 V ± 10%, 6-MHz crystal
VDD = 3 V ± 10%, 4.19 MHz
IDD3 Sub operation mode:
VDD = 3 V, 32768Hz
Main OSC stop, except IVB, IVLD,
Icomp, ILCD and external load.
IDD4 Sub Idle mode;
VDD = 3.0, 32768Hz
Main OSC stop, except IVB, IVLD,
Icomp, ILCD and external load.
IDD5 Stop mode; Main & Sub SCMOD =
OSC stop, VDD=5 V ± 10% 0100B
except IVD, IVLD, Icomp and XTIN = 0V-
external load.
3.5
8
mA
2.5
5.5
1.6
4
1.2
3
1.8
3.5
1.4
3.0
0.6
1.2
0.5
1.1
15
30
uA
6
15
0.3
3
uA
Stop & Sub OSC stop,
VDD = 3 V, except IVD,
IVLD, Lcomp and external
load.
0.1
1
NOTE: Supply current does not include current drawn through internal pull-up resistors or external output current loads.
ILCD is LCD controller/driver operating current, IVB is voltage booster current, Icomp is comparator current and IVLD
is voltage level detector current.
Table 16-3. Data Retention Supply Voltage in Stop Mode
(TA = – 40 °C to + 85 °C)
Parameter
Symbol
Conditions
Min
Typ
Data retention supply
voltage
VDDDR
1.0
-
Data retention supply
IDDDR
VDDDR = 1.0 V
-
-
current
Stop mode; Main & Sub
OSC stop.
except IVB, IVLD, ILCD and
external load.
Max