POWER MANAGEMENT
Applications Information Continued
FIGURE 5: Trip delay Set to 0mS, JP3 Shorted.
Top Trace: Charger Voltage, 5V/div
Bottom Trace: VTRIP, 5V/div
Timebase: 20ms/div
SC1437
FIGURE 6: Internal Trip Voltage (4.7V) Deviation
Plotted Against Temperature.
INTERNAL TRIP VOLTAGE DEVIATION OVER
TEMPERATURE
0.4
0.2
0
-0.2
-0.4
-0.6
-0.8
-1
-40 -20 0 20 40 60 80 100 120
TEMPERATURE (Degrees C)
4.7V Internal
FIGURE 7: Internal Trip Voltage (4.2V) Deviation
Plotted Against Temperature.
INTERNAL TRIP VOLTAGE DEVIATION OVER
TEMPERATURE
0.2
0.1
0
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-40 -20 0 20 40 60 80 100 120
TEMPERATURE (Degrees C)
4.2V Internal
2000 Semtech Corp.
7