AC/DC External Desktop
24 Watts
HUP24 Series
•
XPiQ inc.
Intelligent Design Quality Product
Built-in EMI Filter
•
100% Burn-in
•
Input Surge Current Protection
•
CE Mark
•
Approved to UL, CSA and TUV
Safety Standards
•
Short Circuit Protection
Specification
All specifications typical at nominal line, full load and 25°C
Input
Input Voltage
Input Frequency
Input Current
Leakage Current
• 90-264 VAC
• 47 to 63 Hz
• 0.7A maximum
• 0.75mA maximum
at 240 VAC 50Hz
Output
Output Voltage:
•
Output Current
•
Output Power Range •
Ripple and Noise
•
Overcurrent
•
Protection:
Temperature
•
coefficient:
Transient Response •
5-36 VDC, See table
See Tables
0 to 24 Watts
1% peak to peak max.
All outputs protected to short
circuit conditions
All outputs ±0.04%/°C
maximum
Maximum excursion of 4% or
better on all models. Recovers
to 1% of final value within
500µs after a 25% step load
change
General
Efficiency
Hold-up time
• 60% minimum at 24 watts
• 5 msec minimum
Line Regulation
•
Inrush Current
•
Withstand Voltage •
Insulation Resistance •
Environmental
Operating
•
Temperature
Storage
•
Temperature
MTBF
•
EMI Requirement •
Safety Requirements •
±0.5% maximum at full load
15A at 115 VAC or
30A at 230 VAC at 25°C
cold start
3000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
50 Mohm minimum from
output to ground
0°C to +70°C*
-40°C to +85°C
100,000 hours minimum at full load
at 25°C ambient
Meets conducted and radiated
limits of
a) FCC 20780 Level B
b) CISPR 22 Class B
Approved to:
a) UL 1950
b) CSA C22.2 No. 234
c) EN60950
•
www.XPiQ.com
* Derate linearly from 100% load at 40°C to 50% load at 70°C
PH: 508 429.9883
•
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA