DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MX29F016MI-12 데이터 시트보기 (PDF) - Macronix International

부품명
상세내역
제조사
MX29F016MI-12
Macronix
Macronix International Macronix
MX29F016MI-12 Datasheet PDF : 37 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MX29F016
TABLE1. SOFTWARE COMMAND DEFINITIONS
Command
Bus
Cycle
Reset
1
Read
1
Read Silicon ID
4
Sector Group Protect
4
Verify
Program
4
Chip Erase
6
Sector Erase
6
Sector Erase Suspend 1
Sector Erase Resume 1
First Bus
Second Bus Third Bus Fourth Bus Fifth Bus
Cycle
Cycle
Cycle
Cycle
Cycle
Addr Data Addr Data Addr Data Addr Data Addr Data
XXXH F0H
RA RD
555H AAH 2AAH 55H 555H 90H ADI DDI
555H AAH 2AAH 55H 555H 90H SGA 00H
X02H 01H
555H AAH 2AAH 55H 555H A0H PA PD
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H
XXXH B0H
XXXH 30H
Sixth Bus
Cycle
Addr Data
555H 10H
SA 30H
Note:
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacture code,A1=0, A0 = 1 for device code.
(Refer to Table 3)
DDI = Data of Device identifier : C2H for manufacture code, ADH for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
2.PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address of the sector to be erased.
SGA = Address of the Sector Group Address bits A18-A20 select a uniqul sector group.
3.The system should generate the following address patterns: 555H or 2AAH to Address A10~A0 .
Address bit A11~A20=X=Don't care for all address commands except for Program Address (PA) and Sector
Address (SA). Write Sequence may be initiated with A11~A20 in either state.
4.For Sector Group Protect Verify Operation : If read out data is 01H, it means the sector has been protected.If read
out data is 00H,it means the sector is still not being protected.
COMMAND DEFINITIONS
Device operations are selected by writing specific address
and data sequences into the command register. Writing
incorrect address and data values or writing them in the
improper sequence will reset the device to the read mode.
Table 1 defines the valid register command sequences.
Note that the Erase Suspend (B0H) and Erase Resume
(30H) commands are valid only while the Sector Erase
operation is in progress.
P/N:PM0590
REV. 1.4, NOV. 21, 2002
6

Share Link: 