DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LA9242M 데이터 시트보기 (PDF) - SANYO -> Panasonic

부품명
상세내역
제조사
LA9242M Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Microcontroller Command List
MSB LSB
0 0 0 0 0 0 0 0 RESET
Command
00001000
11110000
11111000
11111111
10010000
FOCUS START
2BYTE-COMMAND DETECT
2BYTE-COMMAND DETECT
2BYTE-COMMAND RESET
FOCUS-OFFSET ADJUST START
1 0 0 1 0 0 0 1 FOCUS-OFFSET ADJUST OFF
1 0 0 1 0 0 1 0 TRACK-OFFSET ADJUST START
10010011
10010100
10010101
10010110
TRACK-OFFSET ADJUST OFF
LASER ON
LASER OFF ; F-SERVO ON
LASER OFF ; F-SERVO OFF
1 0 0 1 0 1 1 1 SPINDLE 8CM
1 0 0 1 1 0 0 0 SPINDLE 12CM
1 0 0 1 1 0 0 1 SPINDLE OFF
1 0 0 1 1 0 1 0 SLED ON
1 0 0 1 1 0 1 1 SLED OFF
1 0 0 1 1 1 0 0 E/F BALANCE START
1 0 0 1 1 1 0 1 TRACK-SERVO OFF
1 0 0 1 1 1 1 0 TRACK-SERVO ON
LA9242M
Reset mode
Power-on mode
Non-adjusted
DSP
RESET (NOTHING)
FOCUS START #1
2BYTE-COMMAND DETECT
2BYTE-COMMAND DETECT
2BYTE-COMMAND RESET
Notes Concerning Microcontroller Program Creation
1. Commands
After sending the FOCUS START command and the E/F BALANCE START command, send 11111110 (FEH) in
order to clear the internal registers of the IC.
Reason : Although the above commands are executed at point ¡ in the timing chart below, the same commands will
be executed again at point if there is subsequent input to CE as shown below.
Timing
2µs or more
1
2
2µs or more
10µs or more
CE
1µs or more
CL
DAT
1µs or more
LSB
MSB
0 0 0 1 0 0 0 0 : “FOCUS START” command
0 0 1 1 1 0 0 1 : “E/F BALANCE START” command
When sending the TRACK-OFFSET ADJUST START command or the FOCUS-OFFSET ADJUST START
command after either VCC ON (POWER ON RESET), RESET command, or a corresponding OFFSET ADJUST
OFF command, waiting time is necessary as listed below. (Only when a 4.2MHz clock is input.)
TRACK-OFFSET ADJUST START : 4ms or more
FOCUS-OFFSET ADJUST START : 4ms or more
2. E/F balance adjustment
E/F balance adjustments should be made in a bit region of the disc, not a mirrored region.
Since there is no track-kick for LA9242M, measures must be taken during EF balance adjustment to obtain a stable
TE signal. (By a sled movement signal from a microcontroller, for example.)
No.7097–10/20

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]