DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CMX624 데이터 시트보기 (PDF) - MX-COM Inc

부품명
상세내역
제조사
CMX624 Datasheet PDF : 25 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Bell 202 and V.23 Compatible Modem
6
CMX624 Preliminary Information
4 General Description
The CMX624 contains a Bell 202 and V.23 compatible FSK modem. This device is capable of duplex
operation at 1200/75bps or 1200/150bps over a 2-wire line interface. It is also capable of 1200/1200bps over
a 4-wire line interface. This device also contains a flexible FSK data UART, a receive FSK or Call Progress
Tone energy detector, a 2100Hz detector, a DTMF generator, a Tx line driving buffer amplifier, a telephone
line Ringing Signal or Line Voltage Reversal detector and a 3.579545MHz Xtal oscillator. These functions are
controlled via a serial interface to the µC, which also carries the transmit and receive FSK modem data.
4.1 ‘C-BUS’ Serial Interface
This block provides for the transfer of data and control or status information between the CMX624’s internal
registers and the µC over the serial interface bus. Each ‘C-BUS’ transaction consists of a single Register
Address byte sent from the µC, as illustrated in Figure 3, which may be followed by either of:
1. A single data byte sent from the µC to be written into one of the CMX624’s Write Only Registers, as
illustrated in Figure 4.
2. A single byte of data read out from one of the CMX624’s Read Only Registers, as illustrated in Figure 5.
Data sent from the µC on the Command Data line is clocked into the CMX624 on the rising edge of the Serial
Clock input. Reply Data sent from the CMX624 to the µC is valid when the Serial Clock is high. The interface
is compatible with the most common µC serial interfaces such as SCI, SPI and Microwire, and may also be
easily implemented with general purpose µC I/O pins controlled by a simple software routine. See Figure 16
for detailed Serial Bus timing requirements.
CS
SERIAL CLOCK
COMMAND DATA
765432 10
REPLY DATA
Address (01 Hex = Reset)
Hi-Z
Note:
The SERIAL CLOCK
line may be high or low at
the start and end of each
transaction.
= Level not important
Figure 3: Serial Bus Transaction (Single byte from µC)
CS
SERIAL CLOCK
COMMAND DATA
765432 10
Address
REPLY DATA
Hi-Z
765432 10
Data to CMX624
Figure 4: Serial Bus Transactions (One Address and one Data byte from µC)
CS
SERIAL CLOCK
COMMAND DATA
765432 10
Address
REPLY DATA
Hi-Z
765432 10
Data from CMX624
Figure 5: Serial Bus Transactions (One Address byte from µC and one Reply byte from CMX624A)
©1999 MX-COM, Inc.
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480180.108
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA