1 2 3 4
Programming
SS-PD: Current Requirem ents (us ing no access ories)
specifications
requirements for
intelligent system
control panels:
The number of devices that can
have their LEDs programmed to
illuminate is limited by the fea-
tures of the panel and the indi-
vidual devices. The actual num-
Pow e r
Supply
Voltage
M ax.
Standby
Current
Max Alarm
Current
Alar m
Re s po ns e
Tim e
24VAC,
30-30VDC 50/60 Hz
26 Ma
87 mA
3 to 17
Sec.
65 mA
RMS
182 mA
RMS
3 to 17
Sec.
120VAC,
50/60 Hz
44 mA
RMS
52 mA
RMS
3 to 17
Sec.
220/240 VAC,
50/60 Hz
25 mA RMS
30 mA RMS
3 to 17 Sec.
ber of devices is determined by
the control panel and its
Pow e r Up
Tim e
2 Sec.
2 Sec.
2 Sec.
2 Sec.
ability to supply LED cur-
rent. Refer to the control
SS-PDR: Relay Contact Ratings
panel installation manual
for details.
Alarm
Auxiliar y
Contacts *
(DPDT)
10 Amp @ 30 VDC
10 Amp @ 277 VAC (0.75 Pow er Factor)
240 VAC @ 249 VAC (0.4 Pow er Factor)
1/8 HP @ 120 VAC
1/4 HP @ 240 VAC
Supe r vis or y
Contact
2.0 Amp @ 30 VDC (resistive)
(SPST)
Minimum sw itching current of 100 mA @ 5 VDC.
Product Line
Information
Model
Description
SS-PD
Duct detector housing with SmartScan
photoelectric smoke detector.
SS-PDR
Duct detector housing with SmartScan
photoelectric smoke detector, DPDT relay.
A5053GM Replacement photoelectric sensor board.
A5067
Replacement power board (without relay).
A5060
Replacement power board (with relay).
ST-1.5
Metal sampling tube, duct widths 1' to 2'
(see table at left for metric lengths).
ST-3
Metal sampling tube, duct widths 2' to 4'.
ST-5
Metal sampling tube, duct widths 4' to 8'.
ST-10
Metal sampling tube, duct widths 8' to 12'.
RA400Z
Remote annunciator alarm LED.
RTS451
Remote test station. Mounts in single-gang
box. Includes red alarm LED and magnet
test switch.
RTS451KEY Key-activated remote test station.
F36-09-11 Replacement filters.
M02-04-00 Replacement test magnet.
S08-39-01 Replacement photo insect screen.
The RA400Z
The RTS451
Specifications
SS-PD
Operating voltage range
15 to 32 VDC.
Standby current
300 µA @ 24 VDC (one communi-
cation every 5 seconds with LED
blink enabled).
Operating temperature range
32° to 131°F (0° to 55°C).
Relative Humidity range
10% to 93% (non-condensing).
Duct air velocity
100 to 4,000 feet/min (0.5 to 20.32
m/s).
Dimensions
14.750" (37 cm) length x 5.500" (14
cm) width x 2.750" (7 cm) deep.
Options
1. RTS-451, RTS-451KEY, RA400Z.
2. PA400 (Review installation instruc-
tions on power requirements).
SS-PDR
Operating voltage range
20 to 30 VDC, 24 VAC/VDC, 120/
240 VAC auxiliary power (requires
a separate auxiliary source).
Standby current
300 µA @ 24 VDC (one communi-
cation every 5 seconds with LED
blink enabled).
Operating temperature range
32° to 131°F (0° to 55°C).
Relative Humidity range
10% to 93% (non-condensing).
Duct air velocity
100 to 4,000 feet/min (0.5 to
20.32 m/s).
Dimensions
14.750" (37 cm) length x 5.500" (14
cm) width x 2.750" (7 cm) deep.
Options
1. RTS-451, RTS-451KEY, RA400Z.
2. PA400 (Review installation instruc-
tions on power requirements).
Page 2 of 4
The RTS451KEY
SS-PD and SS-PDR CS-2463 10/21/04

Share Link: 