STK14CA8
Software Controlled STORE/RECALL Cycle
Symbols
NO.
E Cont G Cont Alt
26 tAVAV tAVAV tRC
27 tAVEL tAVGL tAS
28 tELEH tGLGH tCW
29 tEHAX tGHAX
30 tRECALL tRECALL
Parameter[12,13]
STK14CA8-35 STK14CA8-35 STK14CA8-45
Units Notes
Min Max Min Max Min Max
STORE/RECALL Initiation Cycle 25
35
45
ns 13
Time
Address Setup Time
0
0
0
ns
Clock Pulse Width
20
25
30
ns
Address Hold Time
1
1
1
ns
RECALL Duration
50
50
50 μs
Figure 11. Software STORE/RECALL CYCLE: E Controlled[13]
26
26
27
28
29
23
30
Figure 12. Software STORE/RECALL CYCLE: G Controlled[13]
26
26
27
28
29
23 30
Notes
12. The software sequence is clocked on the falling edge of E controlled READs or G controlled READs
13. The six consecutive addresses must be read in the order listed in the Software STORE/RECALL Mode Selection Table. W must be high during all six consecutive cycles.
Document Number: 001-51592 Rev. **
Page 8 of 16
[+] Feedback