STP08CDC596
Phase Three: “Resuming to Normal Mode”
The sequence for re-entering in normal mode is showed in the following Table and diagram:
Table 11: Resuming to Normal Mode Timing Diagram
CLK
1°
2°
3°
4°
5°
OE/DM2
H
L
H
H
H
LE/DM1
L
L
L
L
L
Figure 16: Resuming to Normal Mode Timing Diagram
For proper device operation the "Entering in detection" sequence must be follow by a "Resume Mode" sequence, isn’t possible to insert con-
secutive equal sequence.
11/20