DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TJA1051T/3 데이터 시트보기 (PDF) - Philips Electronics

부품명
상세내역
제조사
TJA1051T/3
Philips
Philips Electronics Philips
TJA1051T/3 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NXP Semiconductors
TJA1051
High-speed CAN transceiver
6. Functional description
The TJA1051 is a high-speed CAN stand-alone transceiver with Silent mode. It combines
the functionality of the TJA1050 transceiver with improved EMC and ESD handling
capability. Improved slope control and high DC handling capability on the bus pins
provides additional application flexibility.
The TJA1051 is available in two versions, distinguished only by the function of pin 5:
The TJA1051T is 100 % backwards compatible with the TJA1050
The TJA1051T/3 and TJA1051TK/3 allow for direct interfacing to microcontrollers with
supply voltages down to 3 V
6.1 Operating modes
The TJA1051 supports two operating modes, Normal and Silent, which are selectable via
pin S. See Table 3 for a description of the operating modes under normal supply
conditions.
Table 3.
Mode
Normal
Silent
Operating modes
Inputs
Pin S
LOW
LOW
HIGH
Pin TXD
LOW
HIGH
X[2]
Outputs
CAN driver
dominant
recessive
recessive
[1] LOW if the CAN bus is dominant, HIGH if the CAN bus is recessive.
[2] X = don't care
Pin RXD
active[1]
active[1]
active[1]
6.1.1 Normal mode
A LOW level on pin S selects Normal mode. In this mode, the transceiver is able to
transmit and receive data via the bus lines CANH and CANL (see Figure 1 for the block
diagram). The differential receiver converts the analog data on the bus lines into digital
data which is output to pin RXD. The slope of the output signals on the bus lines is
controlled and optimized in a way that guarantees the lowest possible ElectroMagnetic
Emission (EME).
6.1.2 Silent mode
A HIGH level on pin S selects Silent mode. In Silent mode the transmitter is disabled,
releasing the bus pins to recessive state. All other IC functions, including the receiver,
continue to operate as in Normal mode. Silent mode can be used to prevent a faulty CAN
controller from disrupting all network communications.
6.2 Fail-safe features
6.2.1 TXD dominant time-out function
A ‘TXD dominant time-out’ timer is started when pin TXD is set LOW. If the LOW state on
pin TXD persists for longer than tto(dom)TXD, the transmitter is disabled, releasing the bus
lines to recessive state. This function prevents a hardware and/or software application
TJA1051_4
Product data sheet
Rev. 04 — 20 October 2009
© NXP B.V. 2009. All rights reserved.
4 of 18

Share Link: 