MEASUREMENT METHOD (CONT.)
5. Standby Threshold Voltage (Low to High) (V
)
TLH(STBY)
The Pin 5 voltage is measured at the point which changes the device from standby mode into operating mode.
6. Superimpose Threshold Voltage (High to Low) (VTHL(SUPER))
The voltage at TP4 and/or TP5 is slowly decreased. The TP4 and TP5 voltage level is measured at the point at which the
video signal is applied to TP2.
7. Superimpose Threshold Voltage (Low to High) (VTLH(SUPER))
The voltage at TP5 and/or TP4 is slowly increased. The TP4 and TP5 voltage level is measured at the point at which the
character signal or the border signal (in accordance with the Output Truth Table) is applied to TP2.
8. Clamp Voltage (VCMP)
The DC voltage at Pin 1 is measured with no input signal.
9. Character Level (VCHA)
The character level equation is as follows:
VCHA = (V2 - V1)/(1/140)
Where V1 is the measured voltage at TP3 when TP4 and TP5 are at a low level and V2 is the measured voltage at TP3
when TP4 and TP5 are at a high level.
10. Border Level (VBOR)
The border level equation is as follows:
VBOR = (V2 - V1)/(1/140)
Where V1 is the measured voltage at TP3 when TP4 and TP5 are at a low level and V2 is the measured voltage at TP3
when TP4 is at a low level and TP5 is at a high level.
11. Voltage Gain (GVA)
The voltage gain equation is as follows:
GVA = 20 log10 V2/V1
Where V1 is the input voltage at TP1 and V2 is the measured voltage at TP2.
12. Differential Gain (DG)
The differential gain is measured at TP3 when a staircase waveform of 10 steps is applied to TP1.
13. Differential Phase (DP)
The differential phase is measured at TP3 when a staircase waveform of 10 steps is applied to TP1.
14. Frequency Response (fr)
The frequency response equation is as follows:
fr = 20 log10 V2/V1
Where V1 is the measured TP3 voltage when the input frequency is set to 1 MHz and V2 is the measured TP3 voltage
when the input frequency is set to 5 MHz.