DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

RTC200 데이터 시트보기 (PDF) - International Power DC Power Supplies

부품명
상세내역
제조사
RTC200
International-Power-Sources
International Power DC Power Supplies International-Power-Sources
RTC200 Datasheet PDF : 4 Pages
1 2 3 4
150-400 Watts
RTC Series
xppower.com
PICMG 2.11 Compatible
AC or DC Input Versions
Industry Standard
Power Factor Corrected
Hot Swap N+1 Redundancy
Active Current Share
International Safety Approvals
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 90-264 VAC or 36-72 VDC
• 47-63 Hz
• RTC150: 1.8/0.9 A at 115/230 VAC
RTC200: 2.2/1.1 A at 115/230 VAC
RTC400: 4.8/2.4 A at 115/230 VAC
• AC: 30 A at 120 VAC, 60 A at 230 VAC
DC: 40 A at 48 VDC (80 A for 400 W)
• 0.99 typical
• <3 mA
• RTC150/200: 6.3 A fuse
RTC400: 8.0 A fuse
Output
Output Voltage
• 4 outputs with 3.3 V, 5 V and ±12 V
Output Voltage Trim • ±0.25 V on each rail
Initial Set Accuracy • 3.3 V and 5 V: ±10 mV. ±12 V: ±25 mV
Minimum Load
• No minimum load required
Start Up Delay
• 2 s at 115 VAC
Start Up Rise Time
• <75 ms
Hold Up Time
• 10 ms minimum at full load and 90 VAC
Line Regulation
• ±2% max
Load Regulation
• ±2% max (±3% for V4)
Transient Response
• 5% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 1% pk-pk, 20MHz BW
Overvoltage Protection • 110-135% Vnom, recycle input to reset
Overtemperature
Protection
• Shuts down at 110 ˚C, auto recovery,
warning signal at 90 ˚C
measured internally
Overload Protection
• RTC150/200: Latching
RTC400: Auto recovery
Short Circuit Protection • Protected to short circuit conditions
Temperature
Coefficient
• 0.05% /˚C
Remote Sense
• See note 4
Remote Enable
• On = TTL low/short, Off = TTL high/open
Remote Inhibit
• On = TTL high/open, Off = TTL low/short
Current Share
• See note 5
Power Fail
• TTL compatible signal, open collector
active low signal. Indicates any output
below 90% and/or input below 60 VAC for
AC version or 36 VDC for DC version.
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 70% typical
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 135 kHz typical
• RTC150: 2.8 W/In3
RTC200: 3.7 W/In3
RTC400: 3.6 W/In3
• Margining, thermal warning, power fail,
enable and inhibit
• 100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from 100%
power at 50 ˚C to 50% power at 70 ˚C
Cooling
• 400 LFM/30 CFM required for full power
Operating Humidity • 10-95% RH, non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• MIL-STD-810D
Vibration
• MIL-STD-810D
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, level A conducted and radiated
FCC, level A conducted and radiated
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, level 3 Perf Criteria B
• EN61000-4-6 10 V, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950, UL60950, CSA22.2 No. 60950
per cUL, CE Mark

Share Link: 