DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CXA1854AR 데이터 시트보기 (PDF) - Sony Semiconductor

부품명
상세내역
제조사
CXA1854AR Datasheet PDF : 45 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CXA1854AR
Electrical Characteristics – AC Characteristics (5)
Item
Symbol
Filter characteristics
Conditions
Min. Typ. Max. Unit
BPF center
frequency
F0BPFN
F0BPFP
Input SIG6 (VL =0 mV) to (A) and SIG2 (0dB,
frequency variable) to (B). Obtain frequencies
fc1 and fc2 which reduce the output amplitude
by 3dB from the maximum output at TP51 by
changing the frequency, and calculate F0BPF
= (fc1 + fc2)/2. Settings 1 and 3 are required.
NTSC 3.33 3.58 3.83 MHz
PAL
4.13 4.43 4.73 MHz
SW7 = C
Amount of BPF
attenuation
ATBPF
Input SIG6 (VL = 0mV) to (A) and SIG2
2.78MHz –7 –3 –1 dB
(0dB, frequency variable) to (B).
NTSC
Assume TP51 when the center
1.50MHz
–23 –15 dB
frequency is input as 0dB and measure
the output level at TP51 when the
frequencies noted on the right are
input. Settings 1 and 3 are required.
PAL
3.23MHz –8 –3 –1 dB
SW7 = C 2.00MHz
–20 –15 dB
Amount of TRAP
attenuation
ATRAPN
ATRAPP
Input SIG2 (0dB, 3.58MHz, 4.43MHz) to (A) and
measure the output at TP41 with a spectrum
analyzer. Assume the output during Y/C mode
(SW8 = A) as 0dB and measure the amount of
attenuation during COMP mode (SW8 = C).
Settings 1 and 3 are required.
NTSC
PAL
SW7 = C
–35 dB
–35 dB
R-Y, B-Y and LPF DEMLP
characteristics
Input SIG6 (VL = 0mV) to (A) and SIG2 (amplitude
100mV, frequency variable) to (F) and (G). Assume the
output amplitude at TP41 when 100kHz is input as 0dB,
and measure the frequency which attenuates the output
amplitude by –3dB.
0.6 0.8 1.2 MHz
Digital block I/O characteristics
Output transition
time (Note 3 pins)
tTLH
tTHL
Input SIG6 (VL = 0mV) to (A).
Load 30pF (See Fig. 4.)
V3, V46, V58, V59 = 2.5V
30 ns
25 ns
Cross-point time
T
difference
Input SIG6 (VL = 0 mV) to (A).
Load 30pF (see Fig. 5.) HCK1/HCK2
V3, V46, V58, V59 = 2.5V
10 ns
HCK duty
DTYHC
Input SIG6 (VL = 0mV) to (A).
Measure the HCK1 and HCK2 output duty.
Load 30pF
V3, V46, V58, V59 = 2.5V
47 50 53 %
– 19 –

Share Link: 