Nexperia
Table 8. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 11.
Symbol Parameter
Conditions
toff
turn-off time
nE to Vos; see Figure 9
VCC = 2.0 V
VCC = 2.7 V to 3.6 V
VCC = 4.5 V
VCC = 6.0 V
[1] Typical values are measured at nominal VCC and Tamb = 25 C.
[2] tpd is the same as tPLH and tPHL.
[3] ton is the same as tPZH and tPZL.
[4] toff is the same as tPHZ and tPLZ.
[5] CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD VCC2 fi N + [(CL + CS) VCC2 fo] where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
CS = maximum switch capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
[(CL + CS) VCC2 fo] = sum of the outputs.
74LV4066
Quad bilateral switches
Min Typ[1]
[4]
-
-
-
-
-
-
-
-
Max
81
47
40
34
Unit
ns
ns
ns
ns
74LV4066
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 4 — 9 December 2015
© Nexperia B.V. 2017. All rights reserved
10 of 22