10. Don't exceed maximum coil
voltage. Exceeding maximum
allowable coil voltage on continuous
basis will damage the relay and could
case failure.
11. Ensure that the rated contacts
voltage and current values are not
exceeded.
12. The rated control capacity and life
are given as guides.
The contact life is heavily inuenced by
the type of load and other related
conditions, and these factors must be
kept in consideration when using the
relay.
13. If you are using an inductive load
(L load) such that L/R > 1 ms, add
surge protection in parallel with the
inductive load. If this is not done, the
electrical life will decrease and cut-off
failure may occur.
14. When using the 150 A type, mount
it as far away as possible from
Wireless transmitters or devices that
may generate large surges. To prevent
malfunctioning due to high emission
levels, it may be neccessary to take
measures for E.M.I., such as adding a
line noise filter or an electromagnetic
shield.
15. A slight amount of superimposed
line noise may be generated in the
input line the coil current control. It is
recommended to install a line filter to
reduce or eliminate this noise.
16. Ensure that the main terminals are
clean from oils and other foreign
matters. Contamination is likely to
cause increase in the terminal's
temperature.
150A type: nominal cross sectional
area: min. 38mm2.
60A type: nominal cross sectional area:
min. 14mm2.
10A TM type: Faston terminal for #187
tab terminal, 0.5 mm board thickness
(JIS C2809-1992 compliant, at type
connection terminal)
Harness nominal cross sectional area
Load input terminal: min. 1.3 mm2
Coil input terminal: min. 0.3 mm2
17. Avoid excessive stress on the
terminals. Excessive stress can effect
the performance of the contact
operation.
M8 screw terminal (150A main terminal
part)
Terminal pulling up strength ; Max.100N
per terminal
The up-down rotation torque applied to
the terminal ; Max.15Nm
18. Use 40N to 70N of force as a guide
to fasten the terminal connected to the
10A TM type. Please use caution when
inserting or removing the terminal as
the relay tab terminal may cause
injuly.
19. Place the PCB mount type (10A
PCB type) securely by hand soldering
after attaching it. Don't submerge
assembled board in cleaning solution
or water. Also, be careful not let flux
overflow up from the PCB or adhere to
the base of the relay.
20. Make sure the power is turned off
when wiring.
21. Incorrect wiring may cause
unexpected malfunction and failure.
22. For AC cut-off, there is no contact
polarity. Confirm electrical life using
actual load. In the case of DC cut-off,
please note the contact polarity.
23. Lead-free solder (tin, silver and
copper) is used as the spare solder for
the terminals of the PCB mount type
(10A PCB type).
For Cautions for Use, see Relay Technical Information.