DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HMS91C7432 데이터 시트보기 (PDF) - Hynix Semiconductor

부품명
상세내역
제조사
HMS91C7432
Hynix
Hynix Semiconductor Hynix
HMS91C7432 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Hynix semiconductor
Specifications of HMS91C7432
Data format for communication between HMS91C7432 and the host MCU
Sync 1 Sync 2 Contro Length Data 0
0x7E 0xFE l code
Max 131 bytes for data
Data 130
Data Data Reserv Data 0
ID flag ed
Max 128 bytes for data Data
127
Figure 3. Data packet format
Field description :
Field
Sync 1
Sync 2
Control code
Length
Data fields
Data ID
Data Flag
Reserved
Data 0 ~ 127
Description
Value
Synconization for start of Command/Data packet. Always set to 0x7E
As above
Always set to 0xFE
This is the command code field in simple command In simple command
mode. Specify the “Type of command” in complex mode 0x80 ~ 0x89.
command mode.
In complex command
mode 0x00 ~ 0x06
Refer to table 3
Specify the length of the Data field.
0 ~ 131
Max. length of 131 octets for each packet containing Refer to the explaination
structures for complex command data; setup of the communication
parameters; reponse code and mail text contents in mode.
various communication mode accordingly.
Specify the types of data containing in the current 0x00 ~ 0x34
packet.
refer to the table 4
Specify whether the current packet is the last packet or 0x00 more packet follow
more packet follow.
0x01 last packet
Reserved for test purpose. Disregard this field in Not applicable
normal operation.
Contain max 128 octets of data
Single byte data
Table 2. Field descriptions for communication packet
10