HRW0502A
0.4
0A t
0.3
T D = —Tt
Tj = 25°C
0.2
0.1
D=1/6
D=1/3
sin(θ=180°)
D=1/2
DC
2.5
0V
2.0
t
T D = —t
T
Tj = 125°C
1.5
1.0
0.5
D=5/6
D=2/3
D=1/2
sin(θ=180°)
0
0 0.1 0.2 0.3 0.4 0.5
Forward current IF (A)
Fig.4 Forward power dissipation vs. Forward current
0
0 5 10 15 20 25
Reverse voltage VR (V)
Fig.5 Reverse power dissipation vs. Reverse voltage
0.6 VR=VRRM/2
Tj =125°C
Rth(j−a)=340°C/W
0.5
0.4
DC
0.3
0.2
D=1/6
0.1
sin(θ=180°)
D=1/2
D=1/3
0
−25 0 25 50 75 100 125
Ambient temperature Ta (°C)
Fig.6 Average rectified current vs. Ambient temperature
Rev.6.00, Jan.06.2004, page 4 of 5