DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

IL440-6X019T 데이터 시트보기 (PDF) - Vishay Semiconductors

부품명
상세내역
제조사
IL440-6X019T
Vishay
Vishay Semiconductors Vishay
IL440-6X019T Datasheet PDF : 5 Pages
1 2 3 4 5
IL440
Optocoupler, Phototriac Output, Low Vishay Semiconductors
Input Current
ELECTRICAL CHARACTERISTICS (1) (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
PART SYMBOL MIN.
TYP.
MAX.
UNIT
Input
Forward voltage
Reverse voltage
Junction capacitance
Output (2)
IF = 50 mA
IR = 10 μA
VR = 0 V, f = 1 MHz
VF
1.25
V
VR
5
V
Cj
50
pF
IL440-4
400
V
Off-state voltage
IDRM = 500 nA
IL440-5 VD(RMS)
400
V
IL440-6
400
V
Peak on-state voltage
ITM = 100 mA, IFT = 30 mA
VTM
1.5
3
V
Trigger current 1
IL440-4
IFT1
15
V
Trigger current 2
VT = 6 V, RL = 150 Ω IL440-5
IFT2
10
V
Trigger current 3
IL440-6
IFT3
5
V
Critical rate of rise of off-state voltage IF = 0, VD = 0.67 VDRM
dV/dtcr
50
V/μs
Critical rate of rise of on-state current
commutation
IF = 30 mA, VD = 60 VRMS
dV/dtcrq
0.13
0.25
V/μs
Coupler
Holding current
IF 10 mA, VS 3 V
IH
1
mA
Notes
(1) Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
(2) Off-state output terminal voltage (see table 1.)
MAXIMUM SAFETY RATINGS (1)
PARAMETER
INPUT (2)
TEST CONDITION
SYMBOL
MIN.
TYP.
MAX.
UNIT
Forward voltage
OUTPUT
IS, INPUT
130
mA
Power dissipation
PS, OUTPUT
300
mW
Notes
(1) According to DIN EN 60747-5-5. This optocoupler is suitable for safe electrical isolation only within the safety ratings. Compliance with the
safety ratings shall be ensured by means of suitable protective circuits.
(2) The device is used for protective separation agains electrical shock within the maximum safety ratings. This must be ensured by protective
circuits in the applications.
SAFETY AND INSULATION RATINGS
PARAMETER
TEST CONDITION
Climatic classification
(according to IEC68 part 1)
Pollution degree
DIN VDE 0109
Comparative tracking index
VIOTM
VIORM
Insulation resistance at 25 °C
Insulation resistance at TS
Insulation resistance at 100 °C
Partial discharge test voltage
PSO
ISI
TSI
VIO = 500 V
VIO = 500 V
VIO = 500 V
Method a,
Vpd = VIORM x 1.875
SYMBOL
CTI
RIS
RIS
RIS
Vpd
MIN.
175
8000
890
TYP.
55/100/21
2
Document Number: 83631
Rev. 1.9, 29-Oct-10
For technical questions, contact: optocoupleranswers@vishay.com
MAX.
UNIT
1012
109
1011
1669
500
250
175
Vpeak
Vpeak
Ω
Ω
Ω
Vpeak
mW
mA
°C
www.vishay.com
3

Share Link: 