Figure 1. AUTOMATIC PAGE PROGRAM FLOW CHART
START
Write Data AAH Address 5555H
Write Data 55H Address 2AAAH
Write Data A0H Address 5555H
INDEX
MX29F8100
Write Program Data/Address
NO
Loading End?
YES
Wait 100us
Read Status Register
NO
SR7 = 1
?
YES
NO
SR4 = 0
?
YES
Page Program Completed
Program Error
YES
Program
another page?
NO
Operation Done, Device Stays At Read S.R. Mode
To Continue Other Operations,
Do Clear S.R. Mode First
Note : S.R. Stands for Status Register
P/N: PM0262
REV. 2.0, JAN. 22, 1999