DC/DC Converters
TES 3WI Series
3 Watt
Input Specifications
Input current (no load)
24 V models: 20 mA typ.
48 V models: 10 mA typ.
Start-up voltage / under voltage shut down
24 V models: 8.5 VDC / 8 VDC typ.
48 V models: 17 VDC / 16 VDC typ
Surge voltage (1 sec. max.)
24 V models: 50 V max.
48 V models: 100 V max.
Reverse voltage protection 1.0 A max.
Reflected input ripple current
24 V models: 10 mA typ.
48 V models: 5 mA typ.
Input filter EN 55022 class A, FCC part 15, level A
Output Specifications
Voltage set accuracy ±1 %
Regulation
– Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 10 – 100 % single output models: 1.0 % max.
dual output models balanced load: 2.0 % max.
Minimum load 10 % of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experienced)
Temperature coefficient ±0.02 %/°C max.
Ripple and noise 50 mVpk-pk max.
Transient Response (25% load step change)
– Recovery time 500 µs max.
– Deviation 6 % max.
Current limitation >120 % of Iout max.
Short circuit protection continuous, automatic recovery
Capacitive load
single output models: 3000 µF
dual output models: 180 µF (each output)
Remote On/Off
– On: 2.5 to 5.5 V or open circuit
– Off: –0.7 to 0.8 V or short circuit pin 3 and pin 1/2
– Off idle current: 5 mA
General Specifications
Temperature ranges
– Operating –40°C to +71°C
– Case temperature +100°C max.
– Storage –40°C to +125°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at+25°C, ground benign) >1‘000‘000 h
Isolation voltage (60 sec.) – Input/Output 1‘500 VDC
Isolation capacitance
– Input/Output 500 pF max.
Isolation resistance
– Input/Output >1‘000 Mohm
Switching frequency 300 kHz typ. (frequency modulation PFM)
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS Directive 2011/65/EU
Supporting documents: www.tracopower.com/overview/tes3wi
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.