TOL-C31 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Open Frame Power Supplies
TOL Series
10 – 300 Watt
Input Specifications
Input voltage range
Input frequency
Inrush current at 25°C (< 2ms)
Output Specifications
85 – 264 VAC
47 – 63 Hz
15 A max. (Vin 120 VAC)
30 A max. (Vin 230 VAC)
Output voltage adjustment range
± 10 %
Regulation
– Input variation
– Load variation (10 – 100%)
0.5 % max.
0.8 % max.
Ripple and noise (20Mhz Bandwidth)
5VDC output models:
12/24VDC output models:
48VDC output models:
100 mV pp max.
180 mV pp max.
300 mV pp max. (TOL 300: 600mV pp max)
Output current limitation (except for F versions)
105% – 140% of Inom.
Short circuit protection
– 10 to 30 Watt models:
– 50 to 300 Watt models:
hiccup mode, indefinite (automatic recovery)
constant current (automatic recovery)
Overvoltage protection
115 – 135 % Vout nom.
Capacitive load
– TOL10
– TOL15
– other models
10’000 µF max. (24 Vout model: 2’000 µF)
15’000 µF max. (24 Vout model: 6’000 µF)
18’000 µF max.
General Specifications
Temperature ranges
– Operating (ambient temp.)
– Derating above 50°C
– Storage (non operating)
–10 °C…+60°C (TOL150: –10°C...+50°C)
3 %/°C (TOL150: 1.5 %/°C above 35°C)
–20 °C…+ 75 °C
Temperature coefficient
0.02 % / °C
Efficiency
75 % typ.
Humidity (non condensing)
20 % – 90 % rel.
Switching frequency
100 kHz typ. (PWM)
Hold-up time
Isolation voltage
– Input / output
– Input / FG (or case)
– Output / FG (or case)
20 ms typ. at full load
3‘000 VAC for 1min.
2’000 VAC for 1min.
500 VDC for 1min.
Isolation resistance
100 MOhm
Leakage current
0.6 mA RMS typ. / 230 VAC / 60 Hz
Electromagnetic compatibility (EMC) – Conducted input RI suppression EN 55022, class B; FCC Part 15, level B
Emission
– Harmonic current emissions
IEC / EN 61000-3-2, class A
Electromagnetic compatibility (EMC) – Electrostatic discharge
Immunity
– Surge immunity
IEC / EN 61000-4-2 8kV / 15kV
IEC / EN 61000-4-5 2kV / 4kV
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.