NTAG203F
NFC Forum compliant IC with user memory and field detection
7.2.1 Idle state
After a Power-On Reset (POR), the NTAG203F switches directly to the idle state. It only
exits this state when a REQA or a WUPA command is received from the NFC device. Any
other data received while in the idle state is interpreted as an error and the NTAG203F
remains Idle.
After a correctly executed HALT command, the halt state changes to the wait state which
can be exited with a WUPA command.
7.2.2 Ready1 state
In this state, the NTAG203F supports the NFC device when resolving the first part of its
UID (3 bytes) with the ANTICOLLISION or SELECT command from cascade level 1. This
state is exited correctly after execution of either of the following commands:
SELECT command from cascade level 1: the NFC device switches NTAG203F into
Ready2 state where the second part of the UID is resolved.
READ command (from address 0): all anticollision mechanisms are bypassed and
NTAG203F switches directly to the active state.
Remark: If more than one NTAG203F is in the NFC device field, a READ command from
address 0 causes a collision due to the different serial numbers and all NTAG203F
devices are selected. Any other data received in the Ready1 state is interpreted as an
error and depending on its previous state the NTAG203F returns to the wait, idle or halt
state.
7.2.3 Ready2 state
In this state, the NTAG203F supports the NFC device when resolving the second part of
its UID (4 bytes) with the cascade level 2 ANTICOLLISION command. This state is usually
exited using the cascade level 2 SELECT command.
Alternatively, state Ready2 may be skipped using a READ command (from address 0) as
described in state Ready1.
Remark: If more than one NTAG203F is in the NFC device field, a READ command from
address 0 causes a collision due to the different serial numbers and all NTAG203F
devices are selected. The response of the NTAG203F to the cascade level 2 SELECT
command is the Select Acknowledge (SAK) byte. In accordance with ISO/IEC 14443 this
byte indicates if the anticollision cascade procedure has finished. The NTAG203F is now
uniquely selected and only this device will communicate with the NFC device even when
other contactless devices are present in the NFC device field. Any other data received
when the device is in this state is interpreted as an error and depending on its previous
state the NTAG203F returns to the wait, idle or halt state.
7.2.4 Active state
In the active state either a 16-byte READ or 4-byte WRITE command can be performed.
The HALT command exits either the READ or WRITE commands in their active state. Any
other data received when the device is in this state is interpreted as an error and
depending on its previous state the NTAG203F returns to the wait, idle or halt state.