DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PS21661-RZ/-FR 데이터 시트보기 (PDF) - MITSUBISHI ELECTRIC

부품명
상세내역
제조사
PS21661-RZ/-FR
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
PS21661-RZ/-FR Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
MITSUBISHI SEMICONDUCTOR <Single-In-Line Package Intelligent Power Module>
PS21661-RZ /FR
TRANSFER-MOLD TYPE
INSULATED TYPE
Fig. 8 TIMING CHARTS OF THE SIP-IPM PROTECTIVE FUNCTIONS
[A] Short-Circuit Protection (Lower-arms only)
a1. Normal operation : IGBT ON and carrying current.
a2. Short circuit current detection (SC trigger).
a3. Hard IGBT gate interrupt.
a4. IGBT turns OFF.
a5. FO output (20~80µs).
a6. Input L: IGBT OFF state.
a7. Input H: IGBT ON state, but during the FO active signal the IGBT doesnt turn ON.
a8. IGBT OFF state.
Lower-arms control input
Protection circuit state
SET
a6 a7
RESET
Internal IGBT gate
a3
a2
Output current Ic
Sense voltage of the
shunt resistance
SC
a1
a4
a8
SC reference voltage
Error output Fo
CR circuit time constant
DELAY (Note)
a5
Note : The CR time constant safe guards against erroneous SC signal resulting from di/dt generated voltages when IGBT turns ON. The opti-
mum setting for the CR circuit time constant is 1.5~2.0µs.
[B] Under-Voltage Protection (Lower-arms, UVD)
a1. Control supply voltage rises : After the voltage level reaches UVDr, the circuits start to operate when the next input is applied.
a2. Normal operation : IGBT ON and carrying current.
a3. Under voltage trip (UVDt).
a4. IGBT OFF in spite of control input condition.
a5. FO output (20~80µs).
a6. Under voltage reset (UVDr).
a7. Normal operation : IGBT ON and carrying current.
Control input
Protection circuit state
RESET
SET
RESET
UVDBr
Control supply voltage VD
a1
Output current Ic
UVDBt a3
a2
a4
a6
a7
Fault output Fo
a5
Mar. 2004

Share Link: 