M52749FP
Electrical Characteristics Test Method
ICC1 Circuit Current1
Measuring conditions are as listed in supplementary Table.
Measured with a current meter at test point IA.
ICC2 Circuit Current2
Measuring conditions are as listed in supplementary Table.
Measured with a current meter at test point IB.
Vomax Output Dynamic Range
Decrease V34 gradually, and measure the voltage when the bottom of waveform output is distorted. The voltage is
called VOL.
Next, increase V34 gradually, and measure the voltage when the top of waveform output is distorted. The voltage is
called VOH.
Voltage Vomax is calculated by the equation below:
Vomax = VOH − VOL
(V)
VOH
5.0
VOL
0.0
Waveform output
Vimax Maximum Input
Increase the input signal (SG2) amplitude gradually, starting from 700 mVP-P. Measure the amplitude of the input
signal when the output signal starts becoming distorted.
GV Maximum Gain
Input SG1, and read the amplitude output at OUT (33, 38, 41). The amplitude is called VOUT (33, 38, 41).
Maximum gain GV is calculated by the equation below:
VOUT
GV = 20log 0.7 (dB)
∆GV Relative Maximum Gain
Relative maximum gain ∆GV is calculated by the equation below:
∆GV = VOUT (33) / VOUT (38),
VOUT (38) / VOUT (41),
VOUT (41) / VOUT (33)
REJ03F0194-0201 Rev.2.01 Mar 31, 2008