Complete, Direct-Conversion Tuner for
MMDS Applications
Table 4. Charge-Pump Register
BIT NAME
BIT LOCATION (0 = LSB)
CPMP[1:0]
7, 6
CPLIN[1:0]
5, 4
X
3–0
DEFAULT
00
00
X
FUNCTION
Charge-pump minimum pulse width. Users must program to 00
upon powering up the device.
Controls charge-pump linearity.
00 = Typically balanced charge and sink currents.
Other values are not tested.
Don’t care.
Table 5. XTAL Buffer and Reference-Divider Register
BIT NAME
XD[2:0]
BIT LOCATION (0 = LSB)
7, 6, 5
DEFAULT
000
FUNCTION
Sets the crystal-divider setting.
000 = Divide by 1 (default)
001 = Divide by 2
011 = Divide by 3
100 = Divide by 4
101 through 110 = All divide values from 5 (101) to 7 (110)
111 = Divide by 8
Sets the PLL reference-divider (R) number.
00001 = Divide by 1
00010 = Divide by 2
R[4:0]
4–0
00100
00011 = Divide by 3
00100 = Divide by 4 (default)
11111 = Divide by 31
Table 6. PLL Register
BIT NAME
BIT LOCATION (0 = LSB)
D48
7
CPS
6
ICP
5
X
4–0
DEFAULT
1
1
0
X
FUNCTION
VCO divider setting.
0 = Divide by 4. Use for LO frequencies 563MHz.
1 = Divide by 8. Use for LO frequencies < 563MHz.
Charge-pump current mode.
0 = Charge-pump current controlled by ICP bit
1 = Charge-pump current controlled by VCO autoselect (VAS)
Charge-pump current.
0 = 600µA typical
1 = 1200µA typical
Don’t care.