Philips Semiconductors
74LVT16652A
3.3 V 16-bit bus transceiver/register; 3-state
8. Limiting values
Table 5: Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to
GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Max
Unit
VCC
DC supply voltage
IIK
DC input diode
VI < 0 V
current
−0.5
+4.6
V
−50
-
mA
VI
DC input voltage
IOK
DC output diode
VO < 0 V
current
[2] −0.5
+7.0
V
−50
-
mA
VO
DC output voltage
output in OFF or
HIGH-state
[2] −0.5
+7.0
V
IO
DC output current
output in LOW-state
-
128
mA
output in HIGH-state
−64
-
mA
Tstg
storage temperature
Tj
junction temperature
−65
[1] -
+150
°C
150
°C
[1] The performance capability of a high-performance integrated circuit in conjunction with its thermal
environment can create junction temperatures which are detrimental to reliability.
[2] The input and output negative voltage ratings may be exceeded if the input and output clamp current ratings
are observed.
9. Recommended operating conditions
Table 6:
Symbol
VCC
VI
VIH
VIL
IOH
IOL
∆t/∆V
Tamb
Recommended operating conditions
Parameter
Conditions
supply voltage
input voltage
HIGH-level input voltage
LOW-level input voltage
HIGH-level output
current
LOW-level output current
duty cycle ≤ 50 %;
f ≥ 1 kHz
input transition rise or fall outputs enabled
rate
ambient temperature
Min Typ Max Unit
2.7 -
3.6 V
0
-
5.5 V
2.0 -
-
V
-
-
0.8 V
-
-
−32 mA
-
-
32
mA
-
-
64
mA
-
-
10
ns/V
−40 -
+85 °C
9397 750 14402
Product data sheet
Rev. 03 — 12 January 2005
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
9 of 21