1 2
Three phase input type(2-stage filter)
Ordering information
FTB series(80,100,150A) FTB -80 -663 -O
1
2
3
4
1Model Name
R
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
203
663
324
355 *1
Leakage Current
(Input 250/500V 60Hz)
(355only 250/400V 60Hz)
1.0mA/2.0mA max
2.5mA/5.0mA max
12mA/24mA max
330mA/515mA max
Line to ground Line to ground
capacitor CY1 capacitor CY2
(nominal value) (nominal value)
10,000pF
10,000pF
33,000pF
33,000pF
220,000pF
100,000pF
220,000pF
3,300,000pF
*When the line to ground capacitor code is different, the
attenuation characteristic is different.
*1 “355” is applied only to “L” type.
Features of FTB series
Book type (Space-saving type)
- 2-stage filter High-attenuation (150kHz - 1MHz)
- S electable leakage current value,Ultra high attenuation type
"-355-L" for EU (Wye type with neutral earth system)
4 Option
H:Ultra high attenuation type
“355” is not applied
S:Hexagon socket head cap screw
(Standard type is Hexagon head screw)
L:Ultra high attenuation type for EU
Specifications
No. Items
FTB-80-663
FTB-100-663
FTB-150-663
1 Rated Voltage[V]
AC Three Phase 500 (voltage range:528 max) 50/60Hz *2
2 Rated Current[A]
80
100
150
3 Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *3
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW min at room temperature and humidity *4
5 Leakage current 250/500V 60Hz
2.5mA/5.0mA max
6 DC resistance
10mW max
8mW max
6mW max
7 Safety agency approval temperatures
-25 to +85C (Refer to Derating Curve)
8 Operating temperature
-40 to +85C (Refer to Derating Curve)
9 Operating humidity
20 to 95%RH (Non condensing)
10 Storage temperature/humidity
-40 to +85C/20 to 95%RH (Non condensing)
11 Vibration
10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact
196.1m/s2 (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals
UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
14 Case size (without projection)
100X170X350 mm (WXHXD)
[3.94X6.69X13.78 inches]
100X210X400 mm (WXHXD)
[3.94X8.27X15.75 inches]
15 Weight
5.3kg max
7.8kg max
*2 Only capacitor code “355”, Three Phase D-connection : 400 (440 max), Wye-connection : 500 (528 max)
*3 Only capacitor code “324”,”355” 2,800 DC (Cutoff Current = 10mA), 1minute at room temperature and humidity.
*4 Only capacitor code “355”, Isolation resistance specification is deleted.
Circuit Diagram
(1) Line to ground capacitor code : 203, 663, 324
LINE Case
1
2
3
LOAD
4
5
6
(2) FTB-O O-355-L
LINE Case
1
2
3
CY1
CY2
CY1
CY2
CY1, CY2 : Line to ground capacitor
: Mounting Plate
LOAD
4
5
6
Derating Curve
100
80
60
40
20
0
-40 -30 -20 40 50 60 70 80 90
Ambient Temperature [C]
*Keep free ventilation holes for cooling.
FTB-1
CY1
CY2 CY2
CY1
CY1, CY2 : Line to ground capacitor
: Mounting Plate