DC Electrical Characteristics: (TA = 0° to +70°C, VCC = 5V ±5% unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Input Load Current
ILI VIN = 0 to 5.25V
– – 10 µA
Output Leakage Current, High ILOH CE = 2V, VOUT = 2.4V
– – 5 µA
Output Leakage Current, Low ILOL CE = 2V, VOUT = 0.4V
– – –10 µA
Power Supply Current
ICC All Inputs = 5.25V, Data Output Open,
TA = +25°C
– – 45 mA
Power Supply Amp
ICC All Inputs = 5.25V, Data Output Open,
TA = 0°C
– – 50 mA
Output Low Voltage
VOL IOL = 3.2mA
– – 0.4 V
Output High Voltage
VOH IOH = –200µA
2.4 – – V
AC Electrical Characteristics (With Standard Load): (TA = 0° to +70°C, VCC = 5V ±5% unless
otherwise specified)
Parameter
Symbol Test Conditions Min Typ Max Unit
Read Cycle
Read Cycle
Access Time
Chip Enable to Output Time
tRC
350 –
– ns
tA
–
– 350 ns
tCO
–
– 150 ns
Previous Read Data Valid with Respect to Address
tOH1
Previous Read Data Valid with Respect to Chip Enable tOH2
Write Cycle
40 –
0
–
– ns
– ns
Write Cycle
tWC
350 –
– ns
Address to Write Set–Up
tAW
20 –
– ns
Write Pulse Width
Write Recovery Time
Data Set–Up Time
tWP
150 –
– ns
tWR
0
–
– ns
tDW
125 –
– ns
Data Hold Time
tDH
0
–
– ns
Chip Enable to Write Set–Up
tCW
150 –
– ns
AC Electrical Characteristis: (TA = +25°C, f = 1MHz unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Capacitance
Input Capacitance
Output Capacitance
CIN
COUT
All Inputs VIN = 0V
VO = 0V
–
3
5 pF
–
4
6 pF
Standby Characteristics: (TA = 0° to +70°C, Note 2 unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
VCC in Standby
CE Bias in Standby
VPD
VCES
2 ≤ VPD ≤ VCCmax
1.5 ≤ VPD ≤ 2
1.5 –
–
V
2.0 –
–
V
VPD –
–
V
Note 2. Typical values at TA = +25°C.