DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NVD05-SC12-U1 데이터 시트보기 (PDF) - Unspecified

부품명
상세내역
제조사
NVD05-SC12-U1
ETC
Unspecified ETC
NVD05-SC12-U1 Datasheet PDF : 4 Pages
1 2 3 4
ETA-USA
The Power Professionals
MODEL/CHANNEL
Input Voltage 24V
Input Voltage Range
Input Current
Efficiency
Ref. MTBF
Switching Frequency
MODEL/CHANNEL
Input Voltage 48V
Input Voltage Range
Input Current
Efficiency
Ref. MTBF
Switching Frequency
MODEL/CHANNEL
Input Voltage 110V
Input Voltage Range
Input Current
Efficiency
Ref. MTBF
Switching Frequency
Unit
Vdc
Vdc
A
%
H
kHz
Unit
Vdc
Vdc
A
%
H
kHz
Unit
Vdc
Vdc
A
%
H
kHz
NVD3.3-
SC24-U1
NVD05-
SC24-U1
3.3
4.53
90
92
496,000
NVD3.3-
SC48-U1
NVD05-
SC48-U1
1.65
91
NVD3.3-
SD-U1
2.24
93
554,000
NVD05-
SD-U1
0.725
91
91fix.
0.977
93
480,000
NVD12-
SC24-U1
24
19~32
4.89
92
555,000
125fix.
NVD12-
SC48-U1
48
38V~63
2.39
94
125fix.
NVD12-
SD-U1
110
85~140
1.055
93
125fix.
NVD15-
SC24-U1
4.75
92
571,000
NVD15-
SC48-U1
2.33
94
569,000
NVD15-
SD-U1
1.02
93
550,000
NVD24-
SC24-U1
5.4
92
556,000
NVD24-
SC48-U1
2.64
94
562,000
NVD24-
SD-U1
1.16
94
MODEL/CHANNEL
Unit
Environment Operating Temperature
Operating Humidity
Storage Temperature
Withstand Voltage
Primary-Secondary
Derating
Storage Humidity
Isolation Resistance
Shock
Cooling
Vibration
Safety
Protection Over Current Protection
Over Voltage Protection
Input Voltage Protection
Thermal Protection
Dimension Size(WxLxH) / Weight
-10 to 71°C
%
20-80%/RH (non-condensing)
-20 to +85°C
%
Primary-Secondary AC2,000V at 10mA for 1 minute/Primary-Frame Ground
AC2,000V at 10mA for 1 minute/Secondary-Frame Ground AC1,000V at 10mA for 1 minute
-
3.5%/°C (50°C to 71°C)
-
20 to 90%/RH
-
Primary-Secondary-Frame Ground 50M(minimum) by DC500V insulation tester
-
196m/s^2
-
Convection
-
5-10Hz: 10mm double amplitude,10-55Hz: 19.6m/s^2, 20minutes
period for 30 minutes each along X, Y, Z axes(non-operating)
-
UL60950, C-UL(CSA60950), CE
A
Current Limiting
-
Latch Type (output shutdown)
- Output shutdown when input voltage remains under the input range for 3 seconds (typ.)
- Output shutdown when input voltage remains under the input range for 3 seconds (typ.)
mm/g
65Wx101Lx34H mm(Not include output terminal)/250g
* Input fuse is installed in unit
* Common mode filter is installed at the input side of unit
ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 http://www.eta-usa.com
Toll-free (US only): 800-ETA-POWR (800-382-7697) Telephone: 408 778-2793 FAX: 408-779-2753

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]