NXP Semiconductors
SSL4120
Resonant power supply controller IC with PFC for LED lighting
UVP supplies = yes
enable PFC = no
Explanation flow diagram symbols
STATE NAME
-action 1
-action 2
-...
Disabled items are not mentioned
exit condition 1 exit condition 2
reached
reached
exit condition
next state can be entered
from any state when exit
condition is true
START
NO SUPPLY
-All off
UVP supplies = no
DISABLED lC
-Only "Enable lC" detection active
Enable PFC = yes
THERMAL HOLD
-Minimum functionality active
OTP = no
SUPIC CHARGE
-HV start-up source on
UVP SUPIC = no OTP = yes
SUPREG CHARGE
-HV start-up source on
-Series stabilizer on
UVP SUPREG = no UVP SUPIC= yes
OTP = yes
*1Protection timer is activated by:
-UVP output
-OLP HBC
-OCR HBC
-HFP
BOOST CHARGE
-HV start-up source on
-Series stabilizer on
-PFC on
SCP boost = yes
UVP boost = no &
Enable lC = yes
UVP SUPREG = yes
UVP SUPIC = yes
OTP = yes
-Series stabilizer on
-PFC on
-HBC on
SCP boost = yes
Protection timer
passed *1
OPERATIONAL SUPPLY
OVP output =yes
UVP boost = yes
or Enable IC = no
UVP SUPREG = yes
UVP SUPIC = yes
OTP = yes
RESTART
-HV start-up source on
-Restart timer on
Restart time passed
PROTECTION SHUTDOWN
Mains reset = yes
Fig 3. SSL4120 flow diagram