POWER
Data Sheet
Total Power: 40 - 50 W
Input Voltage: 90 - 264 Vac
120 - 370 Vdc
# of Outputs: Single, dual, triple
SPECIAL FEATURES
4.25 x 2.5 x 1.15 inch package
(1U applications)
Universal input
Overvoltage and short circuit
protection
40 W with free air convection
EN55022, EN55011 conducted
emission level B
EN61000-4-2, -3, -4, -5, -6 immunity
compliant
UL, VDE and CSA safety approvals
NLP40 enclosure kit available
RoHS compliant
SAFETY
VDE0805/EN60950/IEC950
File 10401-3336-0093
Licence No. 93662
UL 60950 File No. E132002
CSA C22.2 No. 950
File No. LR41062C
NLP40 Series
Single, Dual and Triple Output
Electrical Specifications
Input
Input voltage range
(See Note 9)
Universal input
Input frequency range
Input surge current
120 Vac, cold start
230 Vac, cold start
Safety ground leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
Input current
120 Vac
230 Vac
Input fuse
UL/IEC127
Output
Total regulation
(Line and load)
Main output
Auxiliary outputs
Rise time
At turn-on
Transient response
Main output
25% step at 0.1 A/µs
Temperature coefficient
Overvoltage protection
Main outputs
Short circuit protection
Cyclic operation
Minimum output current
Single
Multiple
90 - 264 Vac
120 - 370 Vdc
47 - 440 Hz
15 A max.
30 A max.
0.2 mA
0.4 mA
1.4 A rms
0.7 A rms
250 Vac H 3.15 A
±2.0%
±5.0%
1.0 s, max.
5.0% max. dev.,
1 ms rec. to 1.0%
±0.02%/°C
135%, ±15%
Continuous
0A
(See Note 5)