[AK1221]
7. Absolute Maximum Ratings
Table 2 Absolute Maximum Ratings
Parameter
Symbol Min. Max. Unit
Remarks
Supply Voltage
VDD
-0.3 5.5
V
RF Input Power
RFPOW
12 dBm
LO Input Power
LOPOW
12 dBm
Storage Temperature
Tstg
-55
125
C
Exceeding these maximum ratings may result in damage to the AK1221. Normal operation is not guaranteed at
these extremes.
8. Recommended Operating Range
Table 3 Recommended Operating Range
Parameter
Symbol Min. Typ. Max. Unit
Remarks
Operating
Temperature
Ta
-40
85
C
Supply Voltage VDD
4.75
5
5.25
V
The specifications are applicable within the recommended operating range (supply voltage/operating temperature).
MS1400-E-02
7
2013/05