M600 Datasheet PDF : 6 Pages
1 2 3 4 5 6
19” Subracks & Redundant Systems
Front View
Rear View
Description
In addition to a complete range of individual power
supplies we are able to offer a ‘total
solution’ to your power requirements.
Subracks can be configured as 3U, 6U or 9U and
multiples thereof, allowing any mix of units
including ‘hot swap’ redundant systems.
The wide range of options available include input
fuses, circuit breakers, decoupling diodes, RFI
filters, front panels and full system wiring.
Outputs are via DIN rail screw terminals and are
configure to customers requirements to
incorporate DC OK relay contacts, input and
output connections and any other options.
Please contact the sales office for a quotation.
Sample Schematic
Example
The photographs show a typical system containing
a C694-DD.DR which could be configured with
similar units in an N + 1 redundant system.
Specification typically could be:
AC Input: 185-264 V
DC Output: 24 V @ 40 A N + 1 redundancy
Each unit is rated at 20 Amps and is connected in
parallel via decoupling diodes and set up to
current share. In the event of a psu failure the DC
OK alarm relay trips, the failed psu can be
identified by its front panel LED and the psu
replaced without power shut down ie. ‘Hot Swap’.
A full system schematic is provided with each
system as shown below, the size and orientation of
connectors can be specified by the customer.
Standard Options
See Over for Integral PSU Options
3U subrack, 215 or 275 mm deep
6U subrack, 215 or 275 mm deep
6U subrack, configured as 2 x 3U
9U subrack, configured as 3 x 3U
9U subrack, configured as 1 x 3U, 1 x 6U
H15 mating connectors and wiring
DIN rail terminal strip at rear
Input Fuse
up to 25 A
up to 63 A
MCB, single pole
up to 25 A
up to 40 A
up to 63 A
MCB, dual pole
up to 25 A
up to 40 A
up to 63 A
Decoupling Diodes on Heatsink 2 x 50 A
2 x 80 A
The above demonstrates a typical schematic as supplied with each
system. It shows 2 x 2 C694-DD.DR connected in parallel
incorporating option DD (Decoupling Diodes) and DR (DC-OK Relay).
RFI filter, 20-40 dB reduction
up to 10 A
up to 20 A
Front panels, plain or drilled all sizes
Tel: +33 (0)820 801 401 F
Tel: +41 (0)56 483 34 00 CH