DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M600 데이터 시트보기 (PDF) - XP Power Limited

부품명
상세내역
제조사
M600
XPPOWER
XP Power Limited XPPOWER
M600 Datasheet PDF : 6 Pages
1 2 3 4 5 6
Options
Options
Tropical protection
T
Extended temp. range C
Increased mech. strength MS
Options are available, also in combination with other options
Wall mounting
W
Inrush current limiting1) I • • • • * * * * * * • • * * * * * * * * * * * * *
Series diode
SD • • * * * * * * * * * * * * * * * * * * * * * * * *
Anti-parallel diode
AD * * * * * * * * * * * * * * * * * * * * * * * * * *
Autoranging
AU * * * * * * * * * * * * * * * * * * * * * * * *
*
Decoupling diode
DD * * * * * * * * * * * * * * * * * * * * * * * * *
Active current sharing CS
* * * * * * * * * * ••••••• ••••
Inhibit (to be specified) H * * * * * * * * * * * * * * • • • • • • • • • • • • X
Externally programmable E * * * * * * * * * * * * * * * * * * * * * * * * * *
Power fail
P•
• • • • • •• • • • • • • • * • • • • • •• • •X
DC-ok one output
D•
•••• ••• ••••••• * •••• ••••
DC-ok all outputs
M
AC-ok (Inverters)
AC
•X
Sys-reset
Signals with relay
Y
**
••• ••••• * * ••••• ••••
R * * * * * * * * * * * * * * * * * * * * * * * • • •X
1) Standard for mains input model to series C3700
• Option is available, also in combination with other options.
* Option is available with certain restrictions, contact technical sales for details.
X Standard
Options
Option T (Tropical protection):
The unit is given additional protection by a heavy coat of
varnish on the printed circuit board(s) and components.
Option C (Extended temperature range):
Units are designed & tested for operation at an ambient
temperature down to -40 ºC.
Option H (Inhibit):
Operation of the unit is inhibited if a voltage signal (5 V/10
mA) is applied in reference to the negative line of the (main)
output. Alternatively, a connector pin connected to the
negative input line also shuts off the converter (to be
specified). This can also be used in conjunction with a
thermal trip which shuts unit down.
Option MS (Increased mechanical strength):
Screws are fastened by Locktite and heavy components
are fastened by ties or glue to following specification.
Vibration: 2 – 2000 Hz at 2 G, Shock: 10 G for 11 ms to
DIN 40046 part 7.
Option W (Wall mounting):
Module is screwed to a mounting plate for installation
within a cabinet (See C Series in DC-DC Section).
Option SD (Series diode):
To protect the module against input voltage of wrong
polarity, a series diode is provided (efficiency reduces).
Option AD (Anti-parallel diode):
To avoid the power losses of a series diode a diode is
provided with opposite polarity in parallel to the input
blowing an internal or external fuse if the module is
connected to a supply with wrong polarity.
Option E (Programmable by ext. signal):
An ext. signal applied with reference to the negative output
line programs the output voltage.
Option P (Power fail):
A signal (logic or relay) is given if the input voltage drops
below the specified limit. In AC input units we sense the
rectified input voltage so that a power fail alarm can be
avoided if at light load mains power returns before the input
capacitors are substantially discharged.
Option D (DC-ok, one output):
A signal (logic or relay) is given if the voltage of the main
output is below the specified limit. In multi-output systems
the main output is monitored.
Option M (DC-ok, all outputs):
In multi-output systems a signal is provided if the voltage of
any output is below the specified limit.
Option DD (Decoupling diode):
For redundant operation the outputs of two or more units
are paralleled behind de-coupling diodes so that an internal
fault of one module does not affect the operation of the
others. These diodes cause power losses. For high currents
the de-coupling diode may have to be installed externally.
Option SD, AD & DD:
May need to be fitted externally - contact sales office.
Option CS (Active current sharing):
By means of an additional control circuit active current
sharing is provided via an interconnecting wire between 2
or more units.
Option ‘Y’ (Sys-reset):
This logic signal is a combination of power fail and DC-ok
as specified for VME systems.
Option R (Relay):
Options P, D and M are available in conjunction with option
R. A relay is provided for indication instead of a logic signal
with a N.O., N.C. or changeover contact (to be specified).
Option AU (Auto-ranging):
In standard dual AC input units (115/230 V AC) the range is
selected by connecting the input line to different pins on
the connector. With auto-ranging the unit senses the input
voltage and automatically provides the correct connection.
Tel: +44 (0)118 984 5515 UK
Tel: +49 (0)700 9977 1000 D

Share Link: 