DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAPC-104 데이터 시트보기 (PDF) - DATEL Data Acquisition products

부품명
상세내역
제조사
MAPC-104 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
PC/104-Plus Series
46W, TRIPLE OUTPUT DC/DC CONVERTER
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and nominal-load conditions unless noted.
Input
Input Voltage Range
9-32 Volts (12V or 24V Battery)
Transient Voltage Protection
125V/100ms (30kVA)
Overvoltage Shutdown
32-36 Volts (34V typical)
Overvoltage Protection
48V/5 minutes
Start-Up Threshold
9-10 Volts (9.4V typical)
Undervoltage Shutdown
7-9 Volts (8.2V typical)
Input Current
See Performance Specifications
Input Reflected Ripple Current
45mVp-p
Internal Filter Type
Pi
Reverse Polarity Protection
Yes (external fuse mandatory)
Output
Minimum Loading Per Output
No load
Maximum Capacitive Loading
2000µF (+3.3V)
1000µF (+5.1V)
500µF (+12V)
VOUT Accuracy (50% Load)
±3% maximum
Temperature Coefficient
±0.02%/°C
Ripple/Noise (20MHz BW)
See Performance Specifications
Line/Load Regulation
See Performance Specifications
Efficiency
See Performance Specifications
Current Limit Inception
(97% VOUT, each other
output @ 0 Amps)
7-9 Amps (+3.3V)
8.5-11 Amps (+5.1V)
0.2-0.5 Amps (+12V)
Short Circuit Current
(Zener)
2.65 Amps (+3.3V)
3.24 Amps (+5.1V)
0.12 Amps (+12V)
Overvoltage Protection
3.9V (+3.3V)
6V (+5.1V)
13V (+12V)
Power Good
within 7-10% of VOUT
See Tech Notes
(LED and external Signal)
Dynamic Characteristics
Dynamic Load Response
200µsec max. (+3.3V & +5.1V)
(50-100% step to within 1% of VOUT) 100µsec max. (+12V)
Power-up Sequencing
(5.1V power-up before 3.3V)
2-6msec
Power-down Sequencing
(5.1V power-down before 3.3V)
1-4msec
Switching frequency
320kHz (+3.3V & +5.1V)
1120kHz (+12V)
Environmental
Calculated MTBF
TBC million hours
Operating Ambient Temperature
with 100 lfm Air Flow, no Derating
–40 to +85°C
Board Temperature
–40 to +105°C
Thermal Shutdown
+112 to +118°C
Thermal Shutdown Warning
27 to 33 seconds
2nd Level Thermal Shutdown
+122 to +128°C
Storage Temperature
–40 to +105°C
Physical
Dimensions
See Mechanical Dimensions
Connector and Pin Material
According to PC/104-plus Spec
Weight
3.6 ounces (102 grams)
Insulation Level
Non-isolated
All models are tested and specified with a single, external, 0.1µF, multi-layer ceramic output
capacitor on each output and no external input capacitors, unless otherwise noted. All models
will effectively regulate under no-load conditions (with perhaps a slight increase in output
ripple/noise).
See Technical Notes/Performance Curves for additional explanations and details.
Input Ripple Current is tested/specified over a 5-20MHz bandwidth with an external 33µF input
capacitor and a simulated source impedance of 220µF and 12µH. See I/O Filtering, Input Ripple
Current and Output Noise for details.
The Current-Limit-Inception point is the output current level at which the converter's power-
limiting circuitry drops the output voltage 3% from its initial value. See Output Current Limiting
and Short-Circuit Protection for more details.
See Dynamic Load Response for detailed results including switching frequencies.
For Start-Up-Time specifications, output settling time is defined as the output voltage having
reached ±1% of its final value and the load current having reached at least 80% of its
final value.
MTBF is calculated using TELCORDIA SR-332 Method 1 Case 3, ground fixed, +25°C ambient
air and full-load conditions. Contact DATEL for demonstrated life test data.
All models are fully operational and meet all published specifications, including "cold start,"
at –40°C.
The highly unlikely, simultaneous failure of several specific on-board components could
result in the MAPC-104's input voltage appearing at its output, despite the unit's output
overvoltage protection mechanisms. In this rare situation, the Power Good signal
(IPH pin 2, Pwr_LED_Drive) will be deactivated and systems monitoring Power Good will
eventually shut down. If you are using an MAPC-104 to power a load that must be protected
against any and all possible overvoltages, no matter how rare, you will have to provide
the protection external to the MAPC-104. Please contact DATEL for recommendations.
Absolute Maximum Ratings
Input Voltage:
Continuous
Up to 5 minutes maximum
Transient (100ms)
36V
48V
125V (30kVA)
Input Reverse Polarity Protection
External Fuse mandatory
Output current
Current limited. Devices can withstand
an indefinite output short circuit.
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied, nor recommended.
Ordering Guide
Model Number Auxiliary Power Connector (P2)
MAPC-104
Not installed
MAPC-104-5V
Installed
MAPC-104-Y
RoHS-5 hazardous substance compliance, no P2
Connector Designations
The official PC/104 bus specification identifies the standard interboard bus
connections as paired J1/P1 and J2/P2 on one side and J3/P3 on the other
side. However, J1/P1/J2/P2 is physically all one big 4-row connector with J1/
J2 bus receptacle sockets (female) on the top side and P1/P2 pins (male) on
the bottom. This arrangement provides interboard pass-through connections
between PC/104 boards. DATEL refers to this single connector as “J1.”
DATEL’s auxiliary connectors (the IPH and the 5V Auxilliary Power Connec-
tor) are internally designated P1 and P2 respectively and this nomenclature
may appear on the board silkscreening. This is purely an artifact of auto-
mated sequential part numbering in our CAD system and has no relation to
the standard PC/104 interboard bus connectors. Don’t get the connectors
confused since they are all very different types and locations!
4

Share Link: 