DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
5 Operating current
Symbol
ICC1 Burst length = 1
Test condition
MIN. MAX. Unit Notes
/CAS latency = 2
900 mA 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 3
945
Precharge standby current in
ICC2P CKE VIL(MAX.), tCK = 15 ns
9 mA
5 power down mode
ICC2PS CKE VIL(MAX.), tCK =
9
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
180 mA
ICC2NS CKE VIH(MIN.), tCK =
72
Input signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
45 mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
36
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
270 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
180
5 Operating current (Burst mode) ICC4 tCK tCK(MIN.), IO = 0 mA
/CAS latency = 2
1,080 mA 2
5 CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 3
/CAS latency = 2
1,395
2,070 mA 3
5
/CAS latency = 3
2,160
Self refresh current
ICC6 CKE 0.2 V
18 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 9 + 9 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 1.5 + 1.5 µA
High level output voltage
VOH IO = – 4 mA
2.4
V
Low level output voltage
VOL IO = + 4 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).